• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Inner Branch Off the Shelf Technology for Chronic Post-dissection Thoraco-Abdominal Aneurysm with Narrow True Lumen: Results of a European Multicentre Study.

Inner Branch Off the Shelf Technology for Chronic Post-dissection Thoraco-Abdominal Aneurysm with Narrow True Lumen: Results of a European Multicentre Study.

Details
Files
DOI
10.48620/94660
Publisher DOI
10.1016/j.ejvs.2025.04.044
PubMed ID
40288567
Abstract
Objective
This study aimed to evaluate the early and midterm outcomes of endovascular repair of aortic dissection (AD) using a new pre-cannulated, inner branch based, off the shelf stent graft (E-nside; JOTEC, CryoLife, Inc.).Methods
Data from an international multicentre registry on patients treated with the E-nside endograft for AD were analysed. Pre-operative clinical and anatomical characteristics, procedural data, and early and follow up outcomes were recorded in a dedicated electronic data capture system. The primary endpoint was technical success. Secondary endpoints were overall death, aortic related death, aortic related re-intervention rate, endoleak rate, and target vessel instability (TVI) at 30 days and during follow up.Results
Thirty four patients treated in 14 high volume European institutions between January 2020 and May 2024 were included. The mean patient age ± standard deviation was 66 ± 9.8 years, and 30 (88%) were male. The mean true lumen aortic diameter at the visceral aorta was 24.5 ± 7.7 mm. The median procedure time was 300 minutes (interquartile range 215, 373). The technical success rate was 97%, due to one case of placement of the coeliac trunk covered stent into the branch of the superior mesenteric artery and vice versa. The 30 day mortality and re-intervention rates were 6% (n = 2) and 9% (n = 3), respectively. At a mean follow up of 15.1 ± 7.5 months, there were no aortic related deaths. Freedom from aortic related death and all cause death at 12 months was 97% and 94%, respectively. The TVI rate during the follow up was 13% (four of 32). The total re-intervention rate was 16% (five of 32).Conclusion
Endovascular treatment of AD with an off the shelf, inner branched endograft is feasible, with acceptable short and midterm outcomes. The results showed good technical implantation safety and efficacy. Long term follow up results are needed to better define the clinical role of this novel endograft.
Date Issued
2025-10
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Aortic dissection
•
Branched endovascular aortic repair
•
Endovascular repair
•
Multicentre study
•
Thoraco-abdominal aortic aneurysm
Language(s)
en
Author(s)
Tinelli, Giovanni
Lescan, Mario
Sica, Simona
Piazza, Michele
Bisdas, Theodosios
Makaloski, Vladimir  
Clinic of Vascular Surgery  
Bertoglio, Luca
Verzini, Fabio
Pratesi, Giovanni
Tshomba, Yamume
Additional Credits
Clinic of Vascular Surgery  
Journal
European Journal of Vascular and Endovascular Surgery
Publisher
Elsevier
ISSN
1532-2165
1078-5884
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify