  3. Hybrid closed‐loop glucose control with faster insulin aspart (Fiasp) compared with standard insulin aspart in adults with type 1 diabetes: a double‐blind, multicentre, multinational, randomised, crossover study
 

Hybrid closed‐loop glucose control with faster insulin aspart (Fiasp) compared with standard insulin aspart in adults with type 1 diabetes: a double‐blind, multicentre, multinational, randomised, crossover study

Options
  • Details
  • Files
BORIS DOI
10.48350/152733
Publisher DOI
10.1111/dom.14355
PubMed ID
33606901
Description
Objective: We evaluated hybrid closed-loop glucose control with faster-acting insulin aspart (Fiasp) in adults with type 1 diabetes (T1D). We hypothesised that closed-loop with Fiasp provides similar efficacy as closed-loop with standard insulin aspart.

Research design and methods: In a double-blind, multinational, randomised, crossover study, 25 adults with T1D using insulin pump therapy (mean ± SD, age 38 ± 9 years, HbA1c 7.4 ± 0.8% [57 ± 8 mmol/mol]) underwent two 8-week periods of unrestricted living comparing hybrid closed-loop with Fiasp and hybrid closed-loop with standard insulin aspart in random order. During both interventions, the CamAPS FX closed-loop system incorporating Cambridge model predictive control algorithm was used.

Results: In an intention-to-treat analysis, the proportion of time sensor glucose was in target range (3.9-10.0 mmol/L; primary endpoint) was not different between interventions (75 ± 8% vs. 75 ± 8% for hybrid closed-loop with Fiasp vs. hybrid closed-loop with standard insulin aspart; mean-adjusted difference - 0.6 [95%CI -1.8 to 0.7%]; P < 0.001 for non-inferiority [non-inferiority margin 5%]). The proportion of time with sensor glucose <3.9 mmol/L (median [IQR] 2.4 [1.2-3.2%] vs. 2.9 [1.7-4.0%]; P = 0.01) and < 3.0 mmol/L (median [IQR] 0.4 [0.2-0.7%] vs. 0.7 [0.2-0.9%]; P = 0.03) was reduced with Fiasp vs. standard insulin aspart. There was no difference in mean glucose (8.1 ± 0.8 vs. 8.0 ± 0.8 mmol/L; P = 0.13) or glucose variability (SD of sensor glucose 2.9 ± 0.5 vs. 2.9 ± 0.5 mmol/L; P = 0.90). Total daily insulin requirements did not differ (49 ± 15 vs. 49 ± 15 units/day; P = 0.45). No severe hypoglycaemia or ketoacidosis occurred.

Conclusions: The use of Fiasp in CamAPS FX closed-loop system may reduce hypoglycaemia without compromising glucose control compared to standard insulin aspart in adults with T1D. This article is protected by copyright. All rights reserved.
Date of Publication
2021-06
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Boughton, Charlotte K
Hartnell, Sara
Thabit, Hood
Poettler, Tina
Herzig, David
Universitätsklinik für Diabetologie, Endokrinologie, Ernährungsmedizin & Metabolismus (UDEM)
Wilinska, Malgorzata E
Ashcroft, Nicole L
Sibayan, Judy
Cohen, Nathan
Calhoun, Peter
Bally, Lia Claudia
Universitätsklinik für Diabetologie, Endokrinologie, Ernährungsmedizin & Metabolismus (UDEM)
Mader, Julia K
Evans, Mark
Leelarathna, Lalantha
Hovorka, Roman
Additional Credits
Universitätsklinik für Diabetologie, Endokrinologie, Ernährungsmedizin & Metabolismus (UDEM)
Series
Diabetes, obesity and metabolism
Publisher
Wiley
ISSN
1462-8902
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo