• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Characterization of sedation strategies in real-world use of pulsed field ablation Sub-analysis of the EU-PORIA registry.

Characterization of sedation strategies in real-world use of pulsed field ablation Sub-analysis of the EU-PORIA registry.

Details
Files
DOI
10.48620/92496
Publisher DOI
10.1093/europace/euaf287
PubMed ID
41248987
Abstract
Background
With the introduction of pulsed field ablation (PFA) to treat atrial fibrillation (AF), there is interest in studying workflow and sedation strategies to optimize integration into clinical practice. This sub-analysis characterizes early real-world use of general anesthesia versus deep sedation during AF ablation using the pentaspline PFA catheter.Methods
EU-PORIA is an all-comer AF registry enrolling consecutive patients at seven high-volume centers in Europe. Patients were treated based on institutional standard-of-care. During follow-up, any episode of atrial tachycardia (AT) or AF >30s was considered an arrhythmia recurrence.Results
EU-PORIA enrolled 1233 patients, of which 250 (20%) and 983 (80%) cases were performed using general anesthesia and deep sedation, respectively. Patients treated with general anesthesia were more often male and non-paroxysmal AF. In the general anesthesia group, 72% received pulmonary vein isolation (PVI)-only versus 90% in the deep sedation group (p<0.01), and 3D mapping was used in 60% of general anesthesia and 27% of deep sedation cases (p<0.01). Procedure and fluoroscopy times were shorter with deep sedation (51[36-84] vs 75[60-90] min; 13[8-19] vs 19[15-26] min; p<0.01). There were no differences in the incidence of serious adverse events. At 1-year follow-up, 74.8% and 73.8% of patients in the general anesthesia and deep sedation groups, respectively, were free from recurrent AF/AT (p=0.87).Conclusion
AF ablation using deep sedation with the pentaspline PFA catheter demonstrated a safety and efficacy profile consistent with procedures performed under general anesthesia. This characterization of real-world use warrants further evaluation to understand optimal sedation strategies with PFA technologies.
Date Issued
2025-11-17
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
atrial fibrillation
•
catheter ablation
•
pulsed field ablation
•
sedation
Language(s)
en
Author(s)
Chun, Kyoung Ryul Julian
Plank, Karin
Neven, Kars
Reichlin, Tobias  
Clinic of Cardiology  
Blaauw, Yuri
Hansen, Jim
Adelino, Raquel
Ouss, Alexandre
Bordignon, Stefano
Füting, Anna
Roten, Laurent  
Clinic of Cardiology  
Mulder, Bart A
Ruwald, Martin H
Mené, Roberto
van der Voort, Pepijn
Reinsch, Nico
Kueffer, Thomas  
Clinic of Cardiology  
Boveda, Serge
Albrecht, Elizabeth M
Raybuck, Jonathan D
Wehrenberg, Scott
Sutton, Brad S
Schmidt, Boris
Additional Credits
Clinic of Cardiology  
Journal
EP Europace
Publisher
Oxford University Press
ISSN
1532-2092
1099-5129
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify