Unibern.ch
  1. Home
  2. Publications
  3. Comparison of intraoral and laboratory scanners to an industrial-grade scanner while analyzing the fabrication trueness of polymer and titanium complete-arch implant-supported frameworks.

Comparison of intraoral and laboratory scanners to an industrial-grade scanner while analyzing the fabrication trueness of polymer and titanium complete-arch implant-supported frameworks.

Details
Files
DOI
10.48350/186243
Publisher DOI
10.1016/j.jdent.2023.104697
PubMed ID
37696469
Abstract
OBJECTIVES

To compare the scans of different intraoral scanners (IOSs) and laboratory scanners (LBSs) to those of an industrial-grade optical scanner by measuring deviations of complete-arch implant-supported frameworks from their virtual design file.

MATERIAL AND METHODS

Ten polyetheretherketone (PEEK) and 10 titanium (Ti) complete-arch implant-supported frameworks were milled from a master standard tessellation language (STL) file. An industrial-grade blue light scanner (AT), 2 LBSs (MT and E4), and 3 IOSs (PS, T3, and T4) were used to generate STL files of these frameworks. All STLs were imported into an analysis software (Geomagic Control X) and overall root mean square (RMS) values were calculated. Marginal surfaces of all STL files were then virtually isolated (Medit Link v 2.4.4) and marginal RMS values were calculated. Deviations in scans of tested scanners were compared with those in scans of AT by using a linear mixed effects model (α=.05).

RESULTS

When the scans of PEEK frameworks were considered, PS and T3 had similar overall RMS to those of AT (p≥.076). However, E4 and T4 had higher and MT had lower overall RMS than AT (p≤.002) with a maximum estimated mean difference of 13.41 µm. When the scans of Ti frameworks were considered, AT had significantly lower overall RMS than tested scanners (p≤.010) with a maximum estimated mean difference of 31.35 µm. Scans of tested scanners led to significantly higher marginal RMS than scans of AT (p≤.006) with a maximum estimated mean difference of 53.90 µm for PEEK and 40.50 µm for Ti frameworks.

CONCLUSION

Only the PEEK framework scans of PS and T3 led to similar overall deviations to those of AT. However, scans of all tested scanners resulted in higher marginal deviations than those of AT scans.

CLINICAL SIGNIFICANCE

Scans performed by using PS and T3 may be alternatives to those of tested reference industrial scanner AT, for the overall fabrication trueness analysis of complete-arch implant-supported PEEK frameworks.
Date Issued
2023-11
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Complete-arch implant-supported deviation framework intraoral scanner laboratory scanner
Language(s)
en
Author(s)
Yilmaz, Burak  
Zahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie  
Zahnmedizinische Kliniken (ZMK) - Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin  
Dede, Doğu Ömür
Dönmez, Mustafa-Borga  
Zahnmedizinische Kliniken (ZMK) Universität Bern  
Küçükekenci, Ahmet Serkan
Lu, Wei-En
Schumacher, Fernanda
Cakmak, Gülce  
Zahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie  
Additional Credits
Zahnmedizinische Kliniken (ZMK) - Klinik für Zahnerhaltung, Präventiv- und Kinderzahnmedizin  
Zahnmedizinische Kliniken (ZMK) - Klinik für Rekonstruktive Zahnmedizin und Gerodontologie  
Zahnmedizinische Kliniken (ZMK) Universität Bern  
Journal
Journal of dentistry
Publisher
Elsevier
ISSN
1879-176X
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify