• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Acetabular cup anteversion measurement in total hip arthroplasty: reliability of metal artifact reduction MRI compared with CT.

Acetabular cup anteversion measurement in total hip arthroplasty: reliability of metal artifact reduction MRI compared with CT.

Details
Files
DOI
10.48620/94760
Publisher DOI
10.1007/s00256-026-05161-y
PubMed ID
41673173
Abstract
Objective
The acetabular cup version in patients with total hip arthroplasty (THA) is a key parameter influencing hip stability and functional outcomes. Although CT remains the reference standard for assessing cup orientation, MRI with metal artifact reduction techniques is increasingly used for evaluating postoperative pain. This study compared MRI- and CT-based measurements of acetabular cup version regarding agreement, reproducibility, and reliability.Material And Methods
Patients who underwent THA between 2015 and 2025 with postoperative CT and MRI were retrospectively analyzed. MRI was performed using optimized metal artifact reduction sequences. Acetabular cup version was measured on axial high-bandwidth T1-weighted turbo spin-echo sequences and on corresponding CT scans by two musculoskeletal radiologists. Inter- and intra-reader, as well as inter-modality agreement, were assessed using intraclass correlation coefficients (ICC). Bland-Altman plots evaluated systematic bias.Results
Thirty patients were included (mean age, 64.1 years; 14 women). Mean acetabular version was 31.2° (standard deviation (SD), 9.4-10.3) for CT and 30.1-30.2° (SD, 8.9-9.3) for MRI for both readers. Inter-reader agreement was almost perfect for CT (ICC, 0.96) and substantial for MRI (ICC, 0.76). Intra-reader agreement was almost perfect for both modalities (ICC, CT, 0.99; MRI, 0.94). Bland-Altman analysis showed no statistically significant differences between CT and MRI measurements with a slight positive bias for MRI (mean pooled difference, 1.1°; p = 0.058; limits of agreement, -4.7 to 6.8°) and almost perfect agreement for both readers (ICC, 0.86-0.90).Conclusion
MRI measures acetabular cup version with excellent reliability and close agreement with CT, reinforcing MRI's role in postoperative THA evaluation.
Date Issued
2026-06
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Acetabular anteversion measurement
•
Computed tomography
•
Magnetic resonance imaging
•
Metal artifact reduction sequences
•
Prosthetic hip imaging
•
Total hip arthroplasty
Language(s)
en
Author(s)
Abel, Frederik
Zingg, Patrick O
Sutter, Reto
Schmaranzer, Florian  
Institute of Diagnostic, Interventional and Paediatric Radiology  
Additional Credits
Institute of Diagnostic, Interventional and Paediatric Radiology  
Journal
Skeletal Radiology
Publisher
Springer
ISSN
1432-2161
0364-2348
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify