• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Correlation and agreement among outcome measures in implant impression-making research: A validation study.

Correlation and agreement among outcome measures in implant impression-making research: A validation study.

Details
Files
DOI
10.48620/96812
Publisher DOI
10.1016/j.jdent.2026.106624
PubMed ID
41825608
Abstract
Objective
To validate Root Mean Square (RMS) error calculation as an outcome measure of trueness by assessing its correlation and agreement with linear and angular outcome measures in implant impression-making research.Materials And Methods
A maxillary implant cast with four parallel implants was scanned with a high-resolution desktop 3D scanner (Artec Micro II; Artec 3D; Senningerberg, Luxembourg) and scanned 100 times using an intraoral scanner (TRIOS 5; v 22.1.10; 3 Shape; Copenhagen, Denmark) under controlled conditions. Primary outcome measure was trueness, assessed by RMS error, linear and angular inter-implant deviations, and linear and angular intra-implant (platform-level) deviations. Secondary outcome measures included scanning time and number of photograms. Correlations among outcome measures were evaluated using Pearson's correlation coefficients with Bonferroni correction (α = 0.05), and agreement was assessed using Bland-Altman analysis for outcome measures that were directly comparable.Results
Very large positive correlations were found between RMS error and both linear inter-implant deviation (r = 0.831, p = 0.001) and linear intra-implant deviation (r = 0.864, p = 0.001). Angular deviations were not correlated with other outcome measures except between themselves (r = 0.669, p = 0.001). Scanning time was moderately correlated with most deviation outcomes (RMS error: r = 0.478, p = 0.001; linear inter-implant: r = 0.318, p = 0.027; and linear intra-implant deviations: r = 0.319, p = 0.026). The number of photograms was correlated only with scanning time (r = 0.678, p = 0.001) and showed no correlation with deviation measures. RMS error and linear deviations showed partial agreement, whereas angular deviations showed acceptable agreement.Conclusions
RMS error showed strong correlation and partial agreement with linear deviation measures, providing similar but not identical results due to the distinct physical aspects captured by each outcome.
Date Issued
2026-07
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Dental implants
•
Linear discrepancies, Angular discrepancies
•
RMS
•
Root Mean Square
•
Trueness, Precision
Language(s)
en
Author(s)
Limones, Alvaro
Çakmak, Gülce  
School of Dental Medicine, Department of Reconstructive Dentistry and Gerodontology  
Molinero Mourelle, Pedro  
School of Dental Medicine, Department of Reconstructive Dentistry and Gerodontology  
Lin, Wei-Shao
Morton, Dean
Revilla-León, Marta
Gómez-Polo, Miguel
Additional Credits
School of Dental Medicine, Department of Reconstructive Dentistry and Gerodontology  
Journal
Journal of Dentistry
Publisher
Elsevier
ISSN
1879-176X
0300-5712
Access(Rights)
embargo
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify