• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Experimental validation of a mean systemic pressure analog against zero-flow measurements in porcine VA-ECMO.
 

Experimental validation of a mean systemic pressure analog against zero-flow measurements in porcine VA-ECMO.

Options
  • Details
  • Files
BORIS DOI
10.48350/167450
Publisher DOI
10.1152/japplphysiol.00804.2021
PubMed ID
35085032
Description
The mean systemic pressure analog (Pmsa), calculated from running hemodynamic data, estimates mean systemic filling pressure (MSFP). This post hoc study used data from a porcine veno-arterial extracorporeal membrane oxygenation (ECMO) model [n = 9; Sus scrofa domesticus; ES breed (Schweizer Edelschwein)] with eight experimental conditions; Euvolemia [a volume state where ECMO flow produced normal mixed venous saturation (SVO2) without vascular collapse]; three levels of increasing norepinephrine infusion (Vasoconstriction 1-3); status after stopping norepinephrine (Post Vasoconstriction); and three steps of volume expansion (10 mL/kg crystalloid bolus) (Volume Expansion 1-3). In each condition, Pmsa and a "reduced-pump-speed-Pmsa" (Pmsared) were calculated from baseline and briefly reduced pump speeds, respectively. We calculated agreement for absolute values (per condition) and changes (between consecutive conditions) of Pmsa and Pmsared, against MSFP at zero ECMO flow. Euvolemia venous return driving pressure was 5.1 ± 2.0 mmHg. Bland-Altman analysis for Pmsa vs. MSFP (all conditions; 72 data pairs) showed bias (confidence interval) 0.5 (0.1-0.9) mmHg; limits of agreement (LoA) -2.7 to 3.8 mmHg. Bias for ΔPmsa vs. ΔMSFP (63 data pairs): 0.2 (-0.2 to 0.6) mmHg, LoA -3.2 to 3.6 mmHg. Bias for Pmsared vs. MSFP (72 data pairs): 0.0 (-0.3 to -0.3) mmHg; LoA -2.3 to 2.4 mmHg. Bias for ΔPmsared vs. ΔMSFP (63 data pairs) was 0.2 (-0.1 to 0.4) mmHg; LoA -1.8 to 2.1 mmHg. In conclusion, during veno-arterial ECMO, under clinically relevant levels of vasoconstriction and volume expansion, Pmsa accurately estimated absolute and changing values of MSFP, with low between-method precision. The within-method precision of Pmsa was excellent, with a least significant change of 0.15 mmHg.NEW & NOTEWORTHY This is the first study ever to validate the mean systemic pressure analog (Pmsa) against the reference mean systemic filling pressure (MSFP) determined at full arterio-venous pressure equilibrium. Using a porcine ECMO model with clinically relevant levels of vasoconstriction and volume expansion, we showed that Pmsa accurately estimated absolute and changing values of MSFP, with a poor between-method precision. The within-method precision of Pmsa was excellent.
Date of Publication
2022-03-01
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
ECMO cardiac output mean systemic filling pressure mean systemic pressure analog venous return
Language(s)
en
Contributor(s)
Werner-Moller, Per
Heinisch, Paul Philipp
Universitätsklinik für Herz- und Gefässchirurgie
Hana, Anisa
Universitätsklinik für Intensivmedizin
Bachmann, Kaspar
Universitätsklinik für Intensivmedizin
Sondergaard, Soren
Jakob, Stephan
Universitätsklinik für Intensivmedizin
Takala, Jukka
Universitätsklinik für Intensivmedizin
Berger, David
Universitätsklinik für Intensivmedizin
Additional Credits
Universitätsklinik für Herz- und Gefässchirurgie
Universitätsklinik für Intensivmedizin
Series
Journal of applied physiology
Publisher
American Physiological Society
ISSN
1522-1601
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo