Abstract
PURPOSE

This study aimed to explore the concept of total keratometry (TK) by analyzing extensive international datasets representing diverse ethnic backgrounds. The primary objective was to quantify the disparities between traditional keratometry (K) and TK values in normal eyes and assess their impact on intraocular lens (IOL) power calculations using various formulas.

DESIGN

Retrospective multicenter inter-instrument reliability analysis METHODS: The study involved the analysis of biometry data collected from ten international centers across Europe, the United States, and Asia. Corneal power was expressed as equivalent power and astigmatic vector components for both K and TK values. The study assessed the influence of these differences on IOL power calculations using different formulas. The results were analyzed and plotted using Bland-Altman and double angle plots.

RESULTS

The study encompassed a total of 116,982 measurements from 57,862 right eyes and 59,120 left eyes. The analysis revealed a high level of agreement between K and TK values, with 93.98% of eyes exhibiting an absolute difference of 0.25 D or less. Astigmatism vector differences exceeding 0.25 D and 0.50 D were observed in 39.43% and 1.08% of eyes, respectively.

CONCLUSIONS

This large-scale study underscores the similarity between mean K and TK values in healthy eyes, with rare clinical implications for IOL power calculation. Noteworthy differences were observed in astigmatism values between K and TK. Future investigations should delve into the practicality of TK values for astigmatism correction and their implications for surgical outcomes.
Date Issued
2024-04
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Astigmatism Biometry Cataract Surgery Corneal Power Keratometry Swept-Source OCT Total Keratometry
Language(s)
en
Author(s)
Wendelstein, Jascha A
Hoffmann, Peter C
Hoffer, Kenneth J
Langenbucher, Achim
Findl, Oliver
Ruiss, Manuel
Bolz, Matthias
Riaz, Kamran M
Pantanelli, Seth M
Debellemanière, Guillaume
Gatinel, Damien
Cooke, David L
Galzignato, Alice
Yeo, Tun Kuan
Seiler, Günter Theodor Michael  
Universitätsklinik für Augenheilkunde  
Zinkernagel, Martin Sebastian  
Universitätsklinik für Augenheilkunde  
Savini, Giacomo
Additional Credits
Universitätsklinik für Augenheilkunde  
Journal
American journal of ophthalmology
Publisher
Elsevier Science
ISSN
0002-9394
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify