Publication:
Altered blood flow due to larger aortic diameters in patients with transcatheter heart valve thrombosis.

cris.virtual.author-orcid0000-0001-7505-9283
cris.virtual.author-orcid0000-0001-7875-1080
cris.virtual.author-orcid0000-0002-6062-9076
cris.virtualsource.author-orcid5bf6c95f-4573-4c58-a725-e7b9f78c0bcf
cris.virtualsource.author-orcid22d637ee-acea-41c6-9e6a-cb1b0320663f
cris.virtualsource.author-orcidf18733eb-8ab4-40d5-baa0-b444ae63ee84
cris.virtualsource.author-orcidc2344a60-7ad9-44ca-8967-0795ba6620a2
cris.virtualsource.author-orcid31134751-5aa4-429b-82a9-a4f94bac9190
cris.virtualsource.author-orcidfe58815c-ad76-46e4-912c-5be3fa73f92a
datacite.rightsopen.access
dc.contributor.authorJahren, Silje Ekroll
dc.contributor.authorDemirel, Caglayan
dc.contributor.authorBornemann, Karoline-Marie
dc.contributor.authorCorso, Pascal
dc.contributor.authorStortecky, Stefan
dc.contributor.authorObrist, Dominik
dc.date.accessioned2024-10-26T16:48:10Z
dc.date.available2024-10-26T16:48:10Z
dc.date.issued2023-12
dc.description.abstractThe etiology of transcatheter heart valve thrombosis (THVT) and the relevance of the aortic root geometry on the occurrence of THVT are largely unknown. The first aim of this pilot study is to identify differences in aortic root geometry between THVT patients and patients without THVT after transcatheter aortic valve implantation (TAVI). Second, we aim to investigate how the observed difference in aortic diameters affects the aortic flow using idealized computational geometric models. Aortic dimension was assessed using pre-TAVI multi-detector computed tomography scans of eight patients with clinical apparent THVT and 16 unaffected patients (two for each THVT patient with same valve type and size) from the Bern-TAVI registry. Among patients with THVT the right coronary artery height was lower (-40%), and sinotubular junction (STJ) and ascending aorta (AAo) diameters tended to be larger (9% and 14%, respectively) compared to the unaffected patients. Fluid-structure interaction (FSI) in two idealized aortic models with the observed differences in STJ and AAo diameter showed higher backflow rate at the STJ (+16%), lower velocity magnitudes in the sinus (-5%), and higher systolic turbulent dissipation rate in the AAo (+8%) in the model with larger STJ and AAo diameters. This pilot study suggests a direct effect of the aortic dimensions on clinically apparent THVT. The FSI study indicates that larger STJ and AAo diameters potentially favor thrombus formation by increased backflow rate and reduced wash-out efficiency of the sinus. The reported observations require clinical validation but could potentially help identifying patients at risk for THVT.
dc.description.sponsorshipARTORG Center for Biomedical Engineering Research
dc.description.sponsorshipUniversitätsklinik für Kardiologie
dc.description.sponsorshipARTORG Center for Biomedical Engineering Research - Cardiovascular Engineering
dc.identifier.doi10.48350/190652
dc.identifier.pmid38125699
dc.identifier.publisherDOI10.1063/5.0170583
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/172651
dc.language.isoen
dc.publisherAIP Publishing
dc.relation.ispartofAPL bioengineering
dc.relation.issn2473-2877
dc.relation.organizationDE7C6E88B44384ADE0405C82960C5EAC
dc.relation.organizationDCD5A442BB15E17DE0405C82790C4DE2
dc.relation.organizationDCD5A442C258E17DE0405C82790C4DE2
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.subject.ddc500 - Science::570 - Life sciences; biology
dc.subject.ddc600 - Technology::650 - Management & public relations
dc.titleAltered blood flow due to larger aortic diameters in patients with transcatheter heart valve thrombosis.
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.issue4
oaire.citation.startPage046120
oaire.citation.volume7
oairecerif.author.affiliationARTORG Center for Biomedical Engineering Research
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationARTORG Center for Biomedical Engineering Research
oairecerif.author.affiliationARTORG Center for Biomedical Engineering Research - Cardiovascular Engineering
oairecerif.author.affiliationUniversitätsklinik für Kardiologie
oairecerif.author.affiliationARTORG Center for Biomedical Engineering Research - Cardiovascular Engineering
oairecerif.author.affiliation2ARTORG Center for Biomedical Engineering Research - Cardiovascular Engineering
oairecerif.author.affiliation2ARTORG Center for Biomedical Engineering Research - Cardiovascular Engineering
oairecerif.author.affiliation2ARTORG Center for Biomedical Engineering Research - Cardiovascular Engineering
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2023-12-29 04:59:28
unibe.description.ispublishedpub
unibe.eprints.legacyId190652
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
046120_1_5.0170583.pdf
Size:
3.37 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
https://creativecommons.org/licenses/by/4.0
Content:
published

Collections