  3. Equilibrium radionuclide angiography: Intra- and inter-observer repeatability and reproducibility in the assessment of cardiac systolic and diastolic function.

Equilibrium radionuclide angiography: Intra- and inter-observer repeatability and reproducibility in the assessment of cardiac systolic and diastolic function.

Details
Files
DOI
10.7892/boris.137008
Publisher DOI
10.1007/s12350-019-01830-9
PubMed ID
31385225
Abstract
BACKGROUND

This study aimed to assess intra- and inter-observer agreement in assessing the systolic and diastolic function with equilibrium radionuclide angiography (ERNA).

MATERIALS AND METHODS

Thirty-two adults underwent baseline and repeat ERNA. An experienced and a trainee operator analyzed the data by assigning regions of interest manually, fully automatically, and semi-automatically. The Bland-Altman statistic (mean ± 1.96 standard deviations of the differences) was used to assess the repeatability (two different assessments of a single acquisition) and reproducibility (assessments of two different acquisitions).

RESULTS

Using the semi-automated technique the intraobserver repeatability and reproducibility of left ventricular ejection fraction for the experienced physician were - 0.1 ± 3.7 and 0.0 ± 3.8 and for the trainee 2.2 ± 10.6 and 1.9 ± 8.4, respectively. The inter-observer repeatability and reproducibility were - 1.8 ± 6.4 and 0.4 ± 9.0, respectively. Among the parameters of diastolic function, the intraobserver repeatability and reproducibility of the peak filling rate for the experienced physician were - 0.0 ± 1.1 and - 0.1 ± 1.1 and for the trainee 0.2 ± 3.5 and 0.4 ± 3.7, respectively. The inter-observer repeatability and reproducibility were 0.3 ± 1.5 and 0.5 ± 4.0, respectively. Similar was the pattern for the other diastolic indices. In all cases the limits of agreement varied according to the quantification approach.

CONCLUSION

A good repeatability but a moderate reproducibility was found in the assessment of the LVEF. Less good were the findings in the assessment of diastolic function.
Date Issued
2021-08
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
ERNA: planar interobserver intraobserver repeatability reproducibility
Language(s)
en
Author(s)
Sachpekidis, Christos  
Universitätsklinik für Nuklearmedizin  
Sachpekidis, Vasileios
Kopp-Schneider, Annette
Arsos, George
Moralidis, Efstratios
Additional Credits
Universitätsklinik für Nuklearmedizin  
Journal
Journal of nuclear cardiology
Publisher
Springer
ISSN
1071-3581
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify