Description
Background
Coronary access after transcatheter aortic valve replacement (TAVR) remains challenging, particularly with tall-framed valves (TFVs), raising concerns about long-term percutaneous coronary intervention (PCI).Objectives
The aim of this study was to evaluate the impact of bioprosthetic aortic valve type on long-term clinical outcomes in patients undergoing PCI following TAVR.Methods
Data were derived from the multicenter REVIVAL-PCI registry, which included patients from 21 European centers who underwent PCI after TAVR between 2008 and 2023. Patients were classified according to valve frame height: TFVs or short-framed valves (SFVs). The primary endpoint was the 4-year incidence of major adverse cardiovascular events, defined as the composite of cardiovascular death, myocardial infarction, or stroke. Cumulative event rates were estimated using Kaplan-Meier method, and weighted Cox regression models using an entropy balance approach were used to adjust for imbalances in clinical and procedural confounders.Results
The analysis included 441 patients, with 230 having undergone TAVR with SFVs (30.9% women) and 211 with TFVs (44.1% women). The median follow-up after PCI was 908 days (Q1-Q3: 322-1,728 days). The 4-year incidence of major adverse cardiovascular events was comparable between the SFV and TFV groups (38.1% [95% CI: 24.6%-43.9%] vs 31.9% [95% CI: 24.8%-41.0%]; HR: 1.04; 95% CI: 0.71-1.52; P = 0.846). Similar findings were observed after adjustment for potential confounders.Conclusions
In current practice, long-term outcomes after PCI in TAVR patients do not appear to be significantly different between those receiving SFVs and TFVs. Future investigations with newer generation valves and refined implantation techniques are needed to clarify these associations and optimize management strategies.
Date of Publication
2026-02-09
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
PCI
•
TAVR
•
short-framed valve
•
tall-framed valve
Language(s)
en
Contributor(s)
Pivato, Carlo A
Di Angelantonio, Emanuele
Tartaglia, Francesco
Condorelli, Gianluigi
Fontana, Nicole
Ieva, Francesca
Godino, Cosmo
Nakase, Masaaki
Hug, Karsten
Rheude, Tobias
Munoz-Garcia, Antonio J
Jimenez Diaz, Victor Alfonso
Ielasi, Alfonso
Barbanti, Marco
Costa, Giuliano
Anzuini, Angelo
Quadri, Giorgio
Lopez-Otero, Diego
Garot, Philippe
Varbella, Ferdinando
Brouwer, Jorn
Gramss, Leon
Cao, Davide
Figliozzi, Stefano
Regazzoli, Damiano
Testa, Luca
Sanz Sanchez, Jorge
Tomii, Daijiro
Clinic of Cardiology
Chieffo, Alaide
Joner, Michael
Sardella, Gennaro
Cerrato, Enrico
Nombela-Franco, Luis
Pilgrim, Thomas
Clinic of Cardiology
Stefanini, Giulio
Additional Credits
Clinic of Cardiology
Clinic of Cardiology
Series
JACC: Cardiovascular Interventions
Publisher
Elsevier
ISSN
1876-7605
1936-8798
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo