• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Do Osteochondroplasty Alone, Intertrochanteric Derotation Osteotomy, and Flexion-Derotation Osteotomy Improve Hip Flexion and Internal Rotation to Normal Range in Hips With Severe SCFE? - A 3D-CT Simulation Study.

Do Osteochondroplasty Alone, Intertrochanteric Derotation Osteotomy, and Flexion-Derotation Osteotomy Improve Hip Flexion and Internal Rotation to Normal Range in Hips With Severe SCFE? - A 3D-CT Simulation Study.

Details
Files
DOI
10.48350/179052
Publisher DOI
10.1097/BPO.0000000000002371
PubMed ID
36808129
Abstract
BACKGROUND

Severe slipped capital femoral epiphysis (SCFE) leads to femoroacetabular impingement and restricted hip motion. We investigated the improvement of impingement-free flexion and internal rotation (IR) in 90 degrees of flexion following a simulated osteochondroplasty, a derotation osteotomy, and a combined flexion-derotation osteotomy in severe SCFE patients using 3D-CT-based collision detection software.

METHODS

Preoperative pelvic CT of 18 untreated patients (21 hips) with severe SCFE (slip-angle>60 degrees) was used to generate patient-specific 3D models. The contralateral hips of the 15 patients with unilateral SCFE served as the control group. There were 14 male hips (mean age 13±2 y). No treatment was performed before CT. Specific collision detection software was used for the calculation of impingement-free flexion and IR in 90 degrees of flexion and simulation of osteochondroplasty, derotation osteotomy, and combined flexion-derotation osteotomy.

RESULTS

Osteochondroplasty alone improved impingement-free motion but compared with the uninvolved contralateral control group, severe SCFE hips had persistently significantly decreased motion (mean flexion 59±32 degrees vs. 122±9 degrees, P<0.001; mean IR in 90 degrees of flexion -5±14 degrees vs. 36±11 degrees, P<0.001). Similarly, the impingement-free motion was improved after derotation osteotomy, and impingement-free flexion after a 30 degrees derotation was equivalent to the control group (113± 42 degrees vs. 122±9 degrees, P=0.052). However, even after the 30 degrees derotation, the impingement-free IR in 90 degrees of flexion persisted lower (13±15 degrees vs. 36±11 degrees, P<0.001). Following the simulation of flexion-derotation osteotomy, mean impingement-free flexion and IR in 90 degrees of flexion increased for combined correction of 20 degrees (20 degrees flexion and 20 degrees derotation) and 30 degrees (30 degrees flexion and 30 degrees derotation). Although mean flexion was equivalent to the control group for both (20 degrees and 30 degrees) combined correction, the mean IR in 90 degrees of flexion persisted decreased, even after the 30 degrees combined flexion-derotation (22±22 degrees vs. 36 degrees±11, P=0.009).

CONCLUSIONS

Simulation of derotation-osteotomy (30 degrees correction) and flexion-derotation-osteotomy (20 degrees correction) normalized hip flexion for severe SCFE patients, but IR in 90 degrees of flexion persisted slightly lower despite significant improvement. Not all SCFE patients had improved hip motion with the performed simulations; therefore, some patients may need a higher degree of correction or combined treatment with osteotomy and cam-resection, although not directly investigated in this study. Patient-specific 3D-models could help individual preoperative planning for severe SCFE patients to normalize the hip motion.

LEVEL OF EVIDENCE

III, case-control study.
Date Issued
2023-02-20
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Author(s)
Lerch, Till  
Universitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie (DIPR)  
Universitätsklinik für Orthopädische Chirurgie und Traumatologie  
Kim, Young-Jo
Kiapour, Ata
Steppacher, Simon Damian  
Universitätsklinik für Orthopädische Chirurgie und Traumatologie  
Boschung, Adam  
Universitätsklinik für Orthopädische Chirurgie und Traumatologie  
Tannast, Moritz  
Universitätsklinik für Orthopädische Chirurgie und Traumatologie  
Siebenrock, Klaus-Arno  
Universitätsklinik für Orthopädische Chirurgie und Traumatologie  
Novais, Eduardo N
Additional Credits
Universitätsklinik für Orthopädische Chirurgie und Traumatologie  
Universitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie (DIPR)  
Journal
Journal of pediatric orthopedics
Publisher
Wolters Kluwer Lippincott Williams & Wilkins
ISSN
0271-6798
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify