Publication:
The Challenges and Pitfalls of Detecting Sleep Hypopnea Using a Wearable Optical Sensor: Comparative Study.

cris.virtualsource.author-orcid8d23e039-9cf0-4618-9fde-4f464ac111c3
datacite.rightsopen.access
dc.contributor.authorZhang, Zhongxing
dc.contributor.authorQi, Ming
dc.contributor.authorHügli, Gordana
dc.contributor.authorKhatami, Ramin
dc.date.accessioned2024-10-05T06:57:53Z
dc.date.available2024-10-05T06:57:53Z
dc.date.issued2021-07-29
dc.description.abstractBACKGROUND Obstructive sleep apnea (OSA) is the most prevalent respiratory sleep disorder occurring in 9% to 38% of the general population. About 90% of patients with suspected OSA remain undiagnosed due to the lack of sleep laboratories or specialists and the high cost of gold-standard in-lab polysomnography diagnosis, leading to a decreased quality of life and increased health care burden in cardio- and cerebrovascular diseases. Wearable sleep trackers like smartwatches and armbands are booming, creating a hope for cost-efficient at-home OSA diagnosis and assessment of treatment (eg, continuous positive airway pressure [CPAP] therapy) effectiveness. However, such wearables are currently still not available and cannot be used to detect sleep hypopnea. Sleep hypopnea is defined by ≥30% drop in breathing and an at least 3% drop in peripheral capillary oxygen saturation (Spo2) measured at the fingertip. Whether the conventional measures of oxygen desaturation (OD) at the fingertip and at the arm or wrist are identical is essentially unknown. OBJECTIVE We aimed to compare event-by-event arm OD (arm_OD) with fingertip OD (finger_OD) in sleep hypopneas during both naïve sleep and CPAP therapy. METHODS Thirty patients with OSA underwent an incremental, stepwise CPAP titration protocol during all-night in-lab video-polysomnography monitoring (ie, 1-h baseline sleep without CPAP followed by stepwise increments of 1 cmH2O pressure per hour starting from 5 to 8 cmH2O depending on the individual). Arm_OD of the left biceps muscle and finger_OD of the left index fingertip in sleep hypopneas were simultaneously measured by frequency-domain near-infrared spectroscopy and video-polysomnography photoplethysmography, respectively. Bland-Altman plots were used to illustrate the agreements between arm_OD and finger_OD during baseline sleep and under CPAP. We used t tests to determine whether these measurements significantly differed. RESULTS In total, 534 obstructive apneas and 2185 hypopneas were recorded. Of the 2185 hypopneas, 668 (30.57%) were collected during baseline sleep and 1517 (69.43%), during CPAP sleep. The mean difference between finger_OD and arm_OD was 2.86% (95% CI 2.67%-3.06%, t667=28.28; P<.001; 95% limits of agreement [LoA] -2.27%, 8.00%) during baseline sleep and 1.83% (95% CI 1.72%-1.94%, t1516=31.99; P<.001; 95% LoA -2.54%, 6.19%) during CPAP. Using the standard criterion of 3% saturation drop, arm_OD only recognized 16.32% (109/668) and 14.90% (226/1517) of hypopneas at baseline and during CPAP, respectively. CONCLUSIONS arm_OD is 2% to 3% lower than standard finger_OD in sleep hypopnea, probably because the measured arm_OD originates physiologically from arterioles, venules, and capillaries; thus, the venous blood adversely affects its value. Our findings demonstrate that the standard criterion of ≥3% OD drop at the arm or wrist is not suitable to define hypopnea because it could provide large false-negative results in diagnosing OSA and assessing CPAP treatment effectiveness.
dc.description.sponsorshipUniversitätsklinik für Neurologie
dc.identifier.doi10.48350/160807
dc.identifier.pmid34326039
dc.identifier.publisherDOI10.2196/24171
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/54187
dc.language.isoen
dc.publisherJMIR Publications
dc.relation.ispartofJournal of medical internet research
dc.relation.issn1438-8871
dc.relation.organizationDCD5A442BAE0E17DE0405C82790C4DE2
dc.subjectcontinuous positive airway pressure therapy near-infrared spectroscopy obstructive sleep apnea oxygen saturation photoplethysmography smartwatch wearable devices
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleThe Challenges and Pitfalls of Detecting Sleep Hypopnea Using a Wearable Optical Sensor: Comparative Study.
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.issue7
oaire.citation.startPagee24171
oaire.citation.volume23
oairecerif.author.affiliationUniversitätsklinik für Neurologie
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2021-11-09 13:43:57
unibe.description.ispublishedpub
unibe.eprints.legacyId160807
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
Zhang__2021__The_Challenges_and_Pitfalls_of_Detecting_Sleep_Hypopnea.pdf
Size:
1008.52 KB
Format:
Adobe Portable Document Format
File Type:
text
License:
https://creativecommons.org/licenses/by/4.0
Content:
published

Collections