• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Automated alternate cover test for 'HINTS' assessment: a validation study.
 

Automated alternate cover test for 'HINTS' assessment: a validation study.

Options
  • Details
  • Files
BORIS DOI
10.48350/162589
Publisher DOI
10.1007/s00405-021-06998-w
PubMed ID
34302212
Description
OBJECTIVE

The alternate cover test (ACT) in patients with acute vestibular syndrome is part of the 'HINTS' battery test. Although quantitative, the ACT is highly dependent on the examiner's experience and could theoretically vary greatly between examiners. In this study, we sought to validate an automated video-oculography (VOG) system based on eye tracking and dedicated glasses.

METHODS

We artificially induced a vertical strabismus to simulate a skew deviation on ten healthy subjects, aged from 26 to 66, using different press-on Fresnel prisms on one eye while recording eye position with VOG of the contralateral eye. We then compared the system's performance to that of a blinded trained orthoptist using conventional, semi-quantitative method of skew measurement known as the alternate prism cover test (APCT) as a gold standard.

RESULTS

We found a significant correlation between the reference APCT and the Skew VOG (Pearson's R2 = 0.606, p < 0.05). There was a good agreement between the two tests (intraclass correlation coefficient 0.852, 95 CI 0.728-0.917, p < 0.001). The overall accuracy of the VOG was estimated at 80.53% with an error rate of 19.46%. There was no significant difference in VOG skew estimations compared with the gold standard except for very small skews.

CONCLUSIONS

VOG offers an objective and quantitative skew measurement and proved to be accurate in measuring vertical eye misalignment compared to the ACT with prisms. Precision was moderate, which mandates a sufficient number of tests per subject.
Date of Publication
2022-06
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
Alternate cover test Skew deviation Test of skew Validation Video-oculography
Language(s)
en
Contributor(s)
Morrison, Miranda Claire
Universitätsklinik für Hals-, Nasen- und Ohrenkrankheiten, Kopf- und Halschirurgie (HNOK)
Kerkeni, Hassen
Universitätsklinik für Neurologie
Korda, Athanasia
Universitätsklinik für Hals-, Nasen- und Ohrenkrankheiten, Kopf- und Halschirurgie (HNOK)
Räss, Simone
Caversaccio, Marco
Universitätsklinik für Hals-, Nasen- und Ohrenkrankheiten, Kopf- und Halschirurgie (HNOK)
Abegg, Mathiasorcid-logo
Universitätsklinik für Augenheilkunde
Schneider, Erich
Mantokoudis, Georgios
Universitätsklinik für Hals-, Nasen- und Ohrenkrankheiten, Kopf- und Halschirurgie (HNOK)
Additional Credits
Universitätsklinik für Hals-, Nasen- und Ohrenkrankheiten, Kopf- und Halschirurgie (HNOK)
Universitätsklinik für Augenheilkunde
Universitätsklinik für Neurologie
Series
European archives of oto-rhino-laryngology
Publisher
Springer
ISSN
0937-4477
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo