• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Label noise and self-learning label correction in cardiac abnormalities classification.
 

Label noise and self-learning label correction in cardiac abnormalities classification.

Options
  • Details
  • Files
BORIS DOI
10.48350/172035
Publisher DOI
10.1088/1361-6579/ac89cb
PubMed ID
35970176
Description
OBJECTIVE

Learning to classify cardiac abnormalities requires large and high-quality labeled datasets, which is a challenge in medical applications. Small datasets from various sources are often aggregated to meet this requirement, resulting in a final dataset prone to label noise owing to inter- and intra-observer variability, and different expertise. It is well known that label noise can affect the performance and generalizability of the trained models. In this work, we explore the impact of label noise and self-learning label correction on the classification of cardiac abnormalities on large heterogeneous datasets of electrocardiogram (ECG) signals.

APPROACH

A state-of-the-art self-learning multi-class label correction method for image classification is adapted to learn a multi-label classifier for electrocardiogram signals. We evaluated our performance using 5-fold cross-validation on the publicly available PhysioNet/Computing in Cardiology (CinC) 2021 Challenge data, with full and reduced sets of leads. Due to the unknown label noise in the testing set, we tested our approach on the MNIST dataset. We investigated the performance under different levels of structured label noise for both datasets.

MAIN RESULTS

Under high levels of noise, the cross-validation results of self-learning label correction showed an improvement of approximately 3% in the Challenge score for the PhysioNet/CinC 2021 Challenge dataset and, an improvement in accuracy of 5$\%$ and reduction of the expected calibration error of 0.03 for the MNIST dataset. We demonstrate that self-learning label correction can be used to effectively deal with the presence of unknown label noise, also when using a reduced number of ECG leads.
Date of Publication
2022-09-05
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
ECG classification deep learning label noise
Language(s)
en
Contributor(s)
Gallego Vázquez, Cristina
Breuss, Alexander
Gnarra, Oriellaorcid-logo
Universitätsklinik für Neurologie
Portmann, Julian
Madaffari, Antonio
Universitätsklinik für Kardiologie
Da Poian, Giulia
Additional Credits
Universitätsklinik für Neurologie
Universitätsklinik für Kardiologie
Series
Physiological measurement
Publisher
Institute of Physics Publishing IOP
ISSN
0967-3334
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo