• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Advancing HR-pQCT-based homogenised FE models with smooth structured hexahedral meshes.
 

Advancing HR-pQCT-based homogenised FE models with smooth structured hexahedral meshes.

Options
  • Details
  • Files
BORIS DOI
10.48620/85192
Publisher DOI
10.1016/j.bone.2025.117394
PubMed ID
39855287
Description
Nonlinear homogenised finite element (hFE) models can accurately predict stiffness and strength of ultra-distal sections of the radius and tibia using in vivo HR-pQCT images. Recent findings showed good stiffness prediction at these distal sections but a limited ability to reproduce experimental strain localisation. The coarseness of voxel-based meshes reduces the computational effort at the cost of heavily simplifying the underlying geometry of the cortex, the gradient of material properties, and the resulting strain distribution. To overcome these limitations, we present a comprehensive approach to generating fully automated, smooth, and structured hexahedral meshes for HR-pQCT scans at the distal radius and tibia. This study used three datasets to validate the proposed hFE pipeline and its short-term repeatability: ex vivo 2nd generation HR-pQCT images of 21 human radii and 25 human tibiae, and 208 in vivo images from same-day repeated scans on 39 individuals. Results show high accuracy in predicting stiffness (tibia: R2=0.94, radius: R2=0.88) and yield force (tibia: R2=0.93, radius: R2=0.95). Mesh sensitivity analysis reveals stabilisation within a ± 3 % error margin. Dice similarity coefficients between mesh and scanned image were >0.99, and good element quality was achieved across the validation datasets (tibia: S-ICNavg=0.809, radius: S-ICNavg=0.764). Along with the improved volumetric representation of distal cortical and trabecular bone geometry and the good element quality, the new pipeline shows gains in computational performance: 11.70±1.49 min for triple-stack tibia images and 11.00±0.97 min for double-stack radius images, respectively. Generating structured meshes with consistent element-to-element correspondence facilitates seamless comparison between patient models or in longitudinal settings, providing an additional clinical information.
Date of Publication
2025-04
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
Bone strength
•
Distal radius
•
Distal tibia
•
Finite element analysis
•
HR-pQCT
•
Osteoporosis
Language(s)
en
Contributor(s)
Poncioni, Simone Luigi
ARTORG Center - Biomechanics
ARTORG Center for Biomedical Engineering Research
Lippuner, Kurt
Clinic of Osteoporosis
Zysset, Philippeorcid-logo
ARTORG Center - Biomechanics
Additional Credits
ARTORG Center - Biomechanics
Clinic of Osteoporosis
Series
Bone
Publisher
Elsevier
ISSN
1873-2763
8756-3282
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo