• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Microcomputed tomography analysis of marginal adaptation and internal fit of zirconia frameworks with direct-to-abutment connections using a deep learning artificial intelligence model.

Microcomputed tomography analysis of marginal adaptation and internal fit of zirconia frameworks with direct-to-abutment connections using a deep learning artificial intelligence model.

Details
Files
DOI
10.48620/97946
Publisher DOI
10.1016/j.prosdent.2026.04.032
PubMed ID
42156249
Abstract
Statement Of Problem
Despite the increased use of direct-to-abutment connections for implant-supported fixed complete dental prostheses (ISFCDPs), limited evidence exists regarding marginal adaptation and internal fit, 2 parameters critical for biomechanical performance.Purpose
This study evaluated the marginal adaptation and internal fit of zirconia frameworks with direct-to-abutment connections compared to conventional titanium base (Ti-base) connections. A novel method for internal fit assessment using a deep learning artificial intelligence (AI) model was also introduced, and level of agreement with traditional measurements was assessed. Internal fit was compared across the 3 designs using both traditional and AI-derived measurements.Material And Methods
Zirconia specimens (n=24) were allocated to 3 groups: frameworks with Ti-base and regular screws (n=8), frameworks fabricated direct-to-abutment with regular screws (n=8), and frameworks fabricated direct-to-abutment with modified screws (n=8). Each specimen underwent microcomputed tomography scanning before and after thermomechanical aging (TMA) to assess internal fit and marginal adaptation. A deep learning-based AI segmentation model was developed using an image processing software program and achieved a final validation loss below 0.01, corresponding to a Dice Similarity Coefficient greater than 0.95. This metric indicates high spatial overlap and robust segmentation of the gap and abutment regions. Volumetric measurements were obtained for 1 straight and 1 angled transmucosal abutment per specimen. Specimens were subjected to 1.2 million loading cycles at 90 N, followed by repeated measurements. Ninety-six sites were evaluated before and after TMA. Two measurements each for straight and angled abutments for the 3 designs were averaged and difference scores were calculated as post-TMA minus pre-TMA values. Nonparametric statistical tests were applied because of heterogeneity of group variances. Post hoc Mann-Whitney U tests, intraclass correlation and Bland-Altman analyses were conducted (α=.05).Results
Significant differences in marginal adaptation among the 3 groups were identified before and after TMA. The Ti-base group demonstrated significantly superior marginal adaptation compared to both direct-to-abutment groups at both time points (z=3.36, P<.001). Significant differences in internal fit were also observed among the 3 groups before and after TMA. Ti-base group showed significantly improved internal fit relative to both direct-to-abutment groups (standardized Mann-Whitney z values ranged from 3.15 to 3.36, P<.001). Intraclass correlations revealed a significant level of agreement between standardized measurements obtained using conventional and AI-based methods (P<.001), and Bland-Altman plots provided support for concurrent validity of the AI-derived measures of internal fit.Conclusions
Ti-base connections in ISFCDPs demonstrated superior marginal adaptation and internal fit compared to direct-to-abutment connections. Both connection designs achieved clinically acceptable internal fit values. For marginal adaptation, the direct-to-abutment regular screw group exceeded the clinically acceptable threshold of 120 µm. A significant level of agreement was found between standardized traditional and AI-derived measurements of internal fit. Bland-Altman plots supported the concurrent validity of the deep learning AI model.
Date Issued
2026-05-19
Publication Type
Article
Language(s)
en
Author(s)
Alzoubi, Fawaz M
Altemimi, Aseel
Nogueira, Liebert Parreiras
Yilmaz, Burak  
School of Dental Medicine, Department of Reconstructive Dentistry and Gerodontology  
School of Dental Medicine, Clinic of Preventive, Restorative and Pediatric Dentistry  
Additional Credits
School of Dental Medicine, Department of Reconstructive Dentistry and Gerodontology  
School of Dental Medicine, Clinic of Preventive, Restorative and Pediatric Dentistry  
Journal
The Journal of Prosthetic Dentistry
Publisher
Elsevier
ISSN
1097-6841
0022-3913
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify