Publication:
Characteristics and dimensions of the infraorbital canal: a radiographic analysis using cone beam computed tomography (CBCT).

cris.virtualsource.author-orciddf0afb16-9307-4080-a60c-21a6a0b942f2
cris.virtualsource.author-orcidd50f63a4-d2dd-4c56-96f9-7ffb042d6eba
cris.virtualsource.author-orcid24af53a0-85b7-4e98-b2be-1c1310d93c30
datacite.rightsopen.access
dc.contributor.authorFontolliet, Marta
dc.contributor.authorBornstein, Michael
dc.contributor.authorvon Arx, Thomas
dc.date.accessioned2024-11-24T08:48:08Z
dc.date.available2024-11-24T08:48:08Z
dc.date.issued2019-02
dc.description.abstractPURPOSE To analyze morphological characteristics and dimensions of the infraorbital canal-groove complex using cone beam computed tomography (CBCT), and to evaluate its relationship with adjacent anatomical structures. METHODS This retrospective study included CBCT scans of 100 patients taken between January and May 2014. Linear measurements of the infraorbital canal (IOC), the infraorbital groove (IOG) and the infraorbital canal-groove complex (IOC/G) were performed. Morphological variants of the IOC related to the maxillary sinus were classified into three types depending on the extent of protrusion of the canal into the sinus. Angles between the IOC and specific landmarks were measured to determine the direction of the IOC relative to the axial (A-ant) and sagittal (A-horiz) planes. RESULTS A total of 127 IOCs were analyzed. The mean length of the IOC/G was 29 ± 3.0 mm. This value comprised the mean distances of the IOC (24.4 ± 2.9 mm) and the IOG (4.6 ± 1.7 mm). For the different types of IOC morphology, Type 1 (IOC embedded in maxillary sinus roof) was the most common (n = 87, 68.5%). The mean angles of A-ant and A-horiz measured 48.9° ± 7.5° and 20.3° ± 7.9°, respectively. CONCLUSION Knowledge of the IOC/G morphology and its variants is important for the prevention of infraorbital nerve injury due to anesthesia or surgical interventions in this area. The presented data of anatomical characteristics of the IOC/G could be helpful for the planning of surgeries in the maxillary region by means of CBCT imaging.
dc.description.numberOfPages11
dc.description.sponsorshipZahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
dc.description.sponsorshipOro-faziales Diagnostikzentrum Weinbergstrasse
dc.description.sponsorshipZahnmedizinische Kliniken, Klinik für Oralchirurgie und Stomatologie
dc.identifier.doi10.7892/boris.131156
dc.identifier.pmid30328488
dc.identifier.publisherDOI10.1007/s00276-018-2108-z
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/190432
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofSurgical and radiologic anatomy
dc.relation.issn0930-1038
dc.relation.organizationDCD5A442B9C0E17DE0405C82790C4DE2
dc.relation.organization2897F63CA3F0484BE053960C5C822C63
dc.subjectCone beam computed tomography Infraorbital canal Infraorbital canal-groove complex Infraorbital groove Maxillary bone
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleCharacteristics and dimensions of the infraorbital canal: a radiographic analysis using cone beam computed tomography (CBCT).
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.endPage179
oaire.citation.issue2
oaire.citation.startPage169
oaire.citation.volume41
oairecerif.author.affiliationZahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
oairecerif.author.affiliationOro-faziales Diagnostikzentrum Weinbergstrasse
oairecerif.author.affiliationZahnmedizinische Kliniken, Klinik für Oralchirurgie und Stomatologie
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.embargoChanged2022-10-18 22:25:02
unibe.date.licenseChanged2019-10-24 18:17:48
unibe.description.ispublishedpub
unibe.eprints.legacyId131156
unibe.journal.abbrevTitleSURG RADIOL ANAT
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
Fontolliet2019_Article_CharacteristicsAndDimensionsOf.pdf
Size:
1.82 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
publisher
Content:
published

Collections