• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Clinical Performance Evaluation of Continuous Glucose Monitoring Systems: A Scoping Review and Recommendations for Reporting.
 

Clinical Performance Evaluation of Continuous Glucose Monitoring Systems: A Scoping Review and Recommendations for Reporting.

Options
  • Details
Publisher DOI
10.1177/19322968231190941
PubMed ID
37599389
Description
The use of different approaches for design and results presentation of studies for the clinical performance evaluation of continuous glucose monitoring (CGM) systems has long been recognized as a major challenge in comparing their results. However, a comprehensive characterization of the variability in study designs is currently unavailable. This article presents a scoping review of clinical CGM performance evaluations published between 2002 and 2022. Specifically, this review quantifies the prevalence of numerous options associated with various aspects of study design, including subject population, comparator (reference) method selection, testing procedures, and statistical accuracy evaluation. We found that there is a large variability in nearly all of those aspects and, in particular, in the characteristics of the comparator measurements. Furthermore, these characteristics as well as other crucial aspects of study design are often not reported in sufficient detail to allow an informed interpretation of study results. We therefore provide recommendations for reporting the general study design, CGM system use, comparator measurement approach, testing procedures, and data analysis/statistical performance evaluation. Additionally, this review aims to serve as a foundation for the development of a standardized CGM performance evaluation procedure, thereby supporting the goals and objectives of the Working Group on CGM established by the Scientific Division of the International Federation of Clinical Chemistry and Laboratory Medicine.
Date of Publication
2023-11
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
accuracy clinical performance evaluation continuous glucose monitoring study design
Language(s)
en
Contributor(s)
Freckmann, Guido
Eichenlaub, Manuel
Waldenmaier, Delia
Pleus, Stefan
Wehrstedt, Stephanie
Haug, Cornelia
Witthauer, Lilianorcid-logo
Universitätspoliklinik für Endokrinologie, Diabetologie und Klinische Ernährung
Jendle, Johan
Hinzmann, Rolf
Thomas, Andreas
Eriksson Boija, Elisabet
Makris, Konstantinos
Diem, Peter
Tran, Nam
Klonoff, David C
Nichols, James H
Slingerland, Robbert J
Additional Credits
Universitätspoliklinik für Endokrinologie, Diabetologie und Klinische Ernährung
Series
Journal of diabetes science and technology
Publisher
Diabetes Technology Society
ISSN
1932-2968
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo