  2. Publications
  3. Technical complications and failures of zirconia-based prostheses supported by implants followed up to 7 years: a case series.
 

Technical complications and failures of zirconia-based prostheses supported by implants followed up to 7 years: a case series.

Options
  • Details
Publisher DOI
10.11607/ijp.3807
PubMed ID
25390869
Description
PURPOSE

To evaluate technical complications and failures of zirconia-based fixed prostheses supported by implants.

MATERIALS AND METHODS

Consecutive patients received zirconia-based single crowns (SCs) and fixed dental prostheses (FDPs) on implants in a private clinical setting between 2005 and 2010. One dentist performed all surgical and prosthetic procedures, and one master technician performed and coordinated all laboratory procedures. One-piece computer-aided design/ computer-assisted manufacture technology was used to fabricate abutments and frameworks, which were directly connected at the implant level, where possible. All patients were involved in a recall maintenance program and were finally reviewed in 2012. Data on framework fractures, chipping of veneering ceramics, and other technical complications were recorded. The primary endpoint was failure of the prostheses, ie, the need for a complete remake. A life table analysis was calculated.

RESULTS

A total of 289 implants supported 193 zirconia-based prostheses (120 SCs and 73 FDPs) in 127 patients (51 men, 76 women; average age: 62.5 ± 13.4 years) who were reviewed in 2012. Twenty-five (13%) prostheses were cemented on 44 zirconia abutments and 168 (87%) prostheses were screw-retained directly at the implant level. Fracture of 3 frameworks (1 SC, 2 FDPs) was recorded, and significant chipping resulted in the remake of 3 prostheses (1 SC, 2 FDPs). The 7-year cumulative survival rate was 96.4% ± 1.99%. Minor complications comprised 5 loose screws (these were retightened), small chips associated with 3 prostheses (these were polished), and dislodgement of 3 prostheses (these were recemented). Overall, 176 prostheses remained free of technical problems.

CONCLUSIONS

Zirconia-based prostheses screwed directly to implants are clinically successful in the short and medium term.
Date of Publication
2014
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Contributor(s)
Kolgeci, Lumni
Zahnmedizinische Kliniken (ZMK)
Mericske, Erno
Worni, Andreas
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Walker, Petra
Zahnmedizinische Kliniken, Kronen- und Brückenprothetik
Katsoulis, Joannis
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Mericske, Regina
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Additional Credits
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Zahnmedizinische Kliniken (ZMK)
Zahnmedizinische Kliniken, Kronen- und Brückenprothetik
Series
International journal of prosthodontics
Publisher
Quintessence Publ.
ISSN
0893-2174
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo