  3. Assessing Spinal Cerebrospinal Fluid Leaks in Spontaneous Intracranial Hypotension With a Scoring System Based on Brain Magnetic Resonance Imaging Findings.
 

Assessing Spinal Cerebrospinal Fluid Leaks in Spontaneous Intracranial Hypotension With a Scoring System Based on Brain Magnetic Resonance Imaging Findings.

Options
  • Details
BORIS DOI
10.7892/boris.126924
Date of Publication
May 1, 2019
Publication Type
Article
Division/Institute

Universitätsklinik fü...

Universitätsinstitut ...

Clinical Trials Unit ...

Contributor
Dobrocky, Tomas
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Grunder, Lorenz Nicolas
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Breiding, Philipe Sebastian
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Branca, Mattia
Clinical Trials Unit Bern (CTU)
Limacher, Andreasorcid-logo
Clinical Trials Unit Bern (CTU)
Institut für Sozial- und Präventivmedizin (ISPM)
Mosimann, Pascal John
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Mordasini, Pasquale Renato
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Zibold, Felix
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Häni, Levin
Universitätsklinik für Neurochirurgie
Jesse, Christopher Marvin
Universitätsklinik für Neurochirurgie
Fung, Christian
Universitätsklinik für Neurochirurgie
Raabe, Andreas
Universitätsklinik für Neurochirurgie
Ulrich, Christian Thomas
Universitätsklinik für Neurochirurgie
Gralla, Jan
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Beck, Jürgen
Universitätsklinik für Neurochirurgie
Piechowiak, Eike Immo
Universitätsinstitut für Diagnostische und Interventionelle Neuroradiologie
Subject(s)

600 - Technology::610...

300 - Social sciences...

Series
JAMA neurology
ISSN or ISBN (if monograph)
2168-6157
Publisher
American Medical Association
Language
English
Publisher DOI
10.1001/jamaneurol.2018.4921
PubMed ID
30776059
Description
Importance

Various signs may be observed on brain magnetic resonance imaging (MRI) in patients with spontaneous intracranial hypotension (SIH). However, the lack of a classification system integrating these findings limits decision making in clinical practice.

Objective

To develop a probability score based on the most relevant brain MRI findings to assess the likelihood of an underlying spinal cerebrospinal fluid (CSF) leak in patients with SIH.

Design, Setting, and Participants

This case-control study in consecutive patients investigated for SIH was conducted at a single hospital department from February 2013 to October 2017. Patients with missing brain MRI data were excluded. Three blinded readers retrospectively reviewed the brain MRI scans of patients with SIH and a spinal CSF leak, patients with orthostatic headache without a CSF leak, and healthy control participants, evaluating 9 quantitative and 7 qualitative signs. A predictive diagnostic score based on multivariable backward logistic regression analysis was then derived. Its performance was validated internally in a prospective cohort of patients who had clinical suspicion for SIH.

Main Outcomes and Measures

Likelihood of a spinal CSF leak based on the proposed diagnostic score.

Results

A total of 152 participants (101 female [66.4%]; mean [SD] age, 46.1 [14.3] years) were studied. These included 56 with SIH and a spinal CSF leak, 16 with orthostatic headache without a CSF leak, 60 control participants, and 20 patients in the validation cohort. Six imaging findings were included in the final scoring system. Three were weighted as major (2 points each): pachymeningeal enhancement, engorgement of venous sinus, and effacement of the suprasellar cistern of 4.0 mm or less. Three were considered minor (1 point each): subdural fluid collection, effacement of the prepontine cistern of 5.0 mm or less, and mamillopontine distance of 6.5 mm or less. Patients were classified into groups at low, intermediate, or high probability of having a spinal CSF leak, with total scores of 2 points or fewer, 3 to 4 points, and 5 points or more, respectively, on a scale of 9 points. The discriminatory ability of the proposed score could be demonstrated in the validation cohort.

Conclusions and Relevance

This 3-tier predictive scoring system is based on the 6 most relevant brain MRI findings and allows assessment of the likelihood (low, intermediate, or high) of a positive spinal imaging result in patients with SIH. It may be useful in identifying patients with SIH who are leak positive and in whom further invasive myelographic examinations are warranted before considering targeted therapy.
Handle
https://boris-portal.unibe.ch/handle/20.500.12422/64525
Show full item
File(s)
FileFile TypeFormatSizeLicensePublisher/Copright statementContent
Dobrocky JAMANeurol 2019.pdfAdobe PDF2.14 MBpublishedOpen
BORIS Portal
Bern Open Repository and Information System
Build: 27ad28 [15.10. 15:21]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo