  3. Final 3-year clinical outcomes following transcatheter aortic valve implantation with a supra-annular self-expanding repositionable valve in a real-world setting: Results from the multicenter FORWARD study.
 

Final 3-year clinical outcomes following transcatheter aortic valve implantation with a supra-annular self-expanding repositionable valve in a real-world setting: Results from the multicenter FORWARD study.

Options
  • Details
  • Files
BORIS DOI
10.48350/163194
Publisher DOI
10.1002/ccd.29889
PubMed ID
34331844
Description
OBJECTIVES

The Evolut R FORWARD study confirmed safety and effectivenesss of the Evolut R THV in routine clinical practice out to 1 year. Herein, we report the final 3-year clinical follow up of the FORWARD study.

BACKGROUND

Transcatheter aortic valve replacement (TAVR) is a proven alternative to surgery in elderly patients with symptomatic severe aortic stenosis. Long-term clinical outcome data with the Evolut R platform are scarce.

METHODS

FORWARD is a prospective multicenter observational study that evaluated the Evolut R system in routine clinical practice at 53 centres. Eligible patients had symptomatic native aortic valve stenosis or failed surgical aortic bioprosthesis and elevated operative risk per Heart-Team assessment. TAVR was attempted in 1039 patients.

RESULTS

Mean age was 81.8 ± 6.2 years, 64.9% were women, STS score was 5.5 ± 4.5% and 34.2% were frail. Rates of all-cause mortality and disabling stroke were 24.8% and 4.8% at 3 years. Early need for a new pacemaker implantation after TAVR (all-cause mortality: with new PPI; 21.0% vs. without; 22.8%, p = 0.55) and the presence of > trace paravalvular regurgitation (all-cause mortality: no or trace; 22.0% vs. ≥ mild; 25.5%, p = 0.29) did not affect survival. Between 1 and 3 years incidence rates of valve related intervention, endocarditis and clinically relevant valve thrombosis were low.

CONCLUSIONS

The Evolut R valve maintained a favorable safety profile through 3 years in routine clinical practice. Rates of transcatheter heart valve-related adverse events were low.
Date of Publication
2022-01-01
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
safety outcomes self-expanding supra-annular transcatheter aortic valve implantation transcatheter aortic valve replacement.
Language(s)
en
Contributor(s)
Van Mieghem, Nicolas M
Windecker, Stephan
Universitätsklinik für Kardiologie
Manoharan, Ganesh
Bosmans, Johan
Bleiziffer, Sabine
Modine, Thomas
Linke, Axel
Scholtz, Werner
Tchétché, Didier
Finkelstein, Ariel
Ito, Saki
Eisenberg, Ruth
Grube, Eberhard
Additional Credits
Universitätsklinik für Kardiologie
Series
Catheterization and cardiovascular interventions
Publisher
Wiley-Blackwell
ISSN
1522-1946
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo