• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Accuracy of single implant scans with a combined healing abutment-scan body system and different intraoral scanners: AAn in vitro study.
 

Accuracy of single implant scans with a combined healing abutment-scan body system and different intraoral scanners: AAn in vitro study.

Options
  • Details
  • Files
BORIS DOI
10.48350/159266
Publisher DOI
10.1016/j.jdent.2021.103773
PubMed ID
34384842
Description
OBJECTIVE

The aim of the present study was to evaluate the accuracy of single implant scans with a combined healing abutment-scan body (CHA-SB) system using different intraoral scanners.

METHODS

A partially edentulous model with an implant was fabricated, and a CHA-SB system was secured on the implant. The model was scanned using an industrial-grade blue light scanner (ATOS Core 80) and a master reference model was generated (MRM). The model was also scanned with 4 different intraoral scanners (IOSs) [(Virtuo Vivo (VV), TRIOS 3 (T3), Omnicam (CO), and Primescan (PS)]. Test scans (n = 8) were superimposed over the MRM using the best fit algorithm (GOM Inspect 2018; GOM GmbH). After superimpositions, distance and angular deviations at selected areas on CHA-SB system were calculated. The data were analyzed with a 1-way ANOVA and Tukey HSD tests for trueness and precision (α=0.05).

RESULTS

The differences in trueness (distance deviations) among tested IOSs were nonsignificant (P=.652). VV presented the highest angular deviations (P ≤.031), and the angular deviations in other IOS scans were not found different (P ≥.378). The precision of distance deviation data was not significantly different among scanners (P=.052). For the precision of angular deviation data, significant differences were found among IOSs (P=.002). Compared with PS (P=.007) and T3 (P=.014), VV had significantly lower precision, which was not significantly different than that of CO (P=.815).

CONCLUSIONS

The accuracy (angular deviation) of scans of a combined healing abutment-scan body system on a single implant varied depending on the IOS. VirtuoVivo scans had the lowest accuracy in terms of angular deviations. When the distance deviation data were considered, scan accuracy of scanners was similar.

CLINICAL SIGNIFICANCE

A recently introduced combined healing abutment-scan body system combines the acquisition of both the implant and the soft tissue. When different intraoral scanners scan the combined healing abutment-scan body system, the scan accuracy may vary.
Date of Publication
2021-10
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
Accuracy Healing abutment-scan body Intraoral scanner Precision Trueness
Language(s)
en
Contributor(s)
Cakmak, Gülce
Zahnmedizinische Kliniken (ZMK)
Donmez, Mustafa Borga
Atalay, Sevda
Yilmaz, Hakan
Kökat, Ali Murat
Yilmaz, Burak
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Additional Credits
Zahnmedizinische Kliniken (ZMK)
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie
Series
Journal of dentistry
Publisher
Elsevier Science
ISSN
0300-5712
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo