• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Acetabular Cartilage Thickness Differs Among Cam, Pincer, or Mixed-Type Femoroacetabular Impingement: A Descriptive Study Using In Vivo Ultrasonic Measurements During Surgical Hip Dislocation.

Acetabular Cartilage Thickness Differs Among Cam, Pincer, or Mixed-Type Femoroacetabular Impingement: A Descriptive Study Using In Vivo Ultrasonic Measurements During Surgical Hip Dislocation.

Details
Files
DOI
10.48350/160098
Publisher DOI
10.1177/1947603521990879
PubMed ID
33550853
Abstract
OBJECTIVE

To investigate acetabular cartilage thickness among (1) 8 measurement locations on the lunate surface and (2) different types of femoroacetabular impingement (FAI).

DESIGN

Prospective descriptive study comparing in vivo measured acetabular cartilage thickness using a validated ultrasonic device during surgical hip dislocation in 50 hips. Measurement locations included the anterior/posterior horn and 3 locations on each peripheral and central aspect of the acetabulum. The clock system was used for orientation. Thickness was compared among cam (11 hips), pincer (8 hips), and mixed-type (31 hips) of FAI. Mean age was 31 ± 8 (range, 18-49) years. Hips with no degenerative changes were included (Tönnis stage = 0).

RESULTS

Acetabular cartilage thickness ranged from 1.7 mm to 2.7 mm and differed among the 8 locations (P < 0.001). Thicker cartilage was found on the peripheral aspect at 11 and 1 o'clock positions (mean of 2.4 mm and 2.7 mm, respectively). At 5 out of 8 locations of measurement (anterior and posterior horn, 1 o'clock peripheral, 12 and 2 o'clock central), cartilage thickness was thinner in hips with pincer impingement compared to cam and/or mixed-type of FAI (P ranging from <0.001 to 0.031). No difference in thickness existed between cam and mixed-type of impingement (P = 0.751).

CONCLUSION

Acetabular cartilage thickness varied topographically and among FAI types. This study provides first baseline information about topographical cartilage thickness in FAI measured in vivo. Thinner cartilage thickness in pincer deformities could be misinterpreted as joint degeneration and could therefore have an impact on indication for hip preserving surgery.
Date Issued
2021-12
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
cartilage thickness femoroacetabular impingement hip joint preserving surgery in vivo ultrasonic
Language(s)
en
Author(s)
Steppacher, Simon Damian  
Universitätsklinik für Orthopädische Chirurgie und Traumatologie  
Meier, Malin Kristin  
Universitätsklinik für Orthopädische Chirurgie und Traumatologie  
Albers, Christoph  
Universitätsklinik für Orthopädische Chirurgie und Traumatologie  
Tannast, Moritz  
Freiburger Spital HFR - Freiburg, Klinik für Orthopädie  
Siebenrock, Klaus-Arno  
Universitätsklinik für Orthopädische Chirurgie und Traumatologie  
Additional Credits
Universitätsklinik für Orthopädische Chirurgie und Traumatologie  
Freiburger Spital HFR - Freiburg, Klinik für Orthopädie  
Journal
Cartilage
Publisher
Sage
ISSN
1947-6035
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify