• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Glenoid component placement in reverse shoulder arthroplasty assisted with augmented reality through a head-mounted display leads to low deviation between planned and post-operative parameters.

Glenoid component placement in reverse shoulder arthroplasty assisted with augmented reality through a head-mounted display leads to low deviation between planned and post-operative parameters.

Details
Files
DOI
10.48350/183191
Publisher DOI
10.1016/j.jse.2023.05.002
PubMed ID
37276917
Abstract
BACKGROUND

Navigated augmented reality (AR) through a head-mounted display (HMD) may lead to accurate glenoid component placement in reverse shoulder arthroplasty (RSA). The purpose of this study is to evaluate the deviation between planned, intra- and postoperative inclination, retroversion, entry point, depth and rotation of the glenoid component placement assisted by a navigated AR through HMD during RSA.

METHODS

Both shoulders of six fresh frozen human cadavers, free from fractures or other bony pathologies, were used. Preoperative computed tomography (CT) scans were used for the three-dimensional (3D) planning. The glenoid component placement was assisted using a navigated AR system through a HMD in all specimens. Intraoperative inclination, retroversion, depth and rotation were measured by the system. A postoperative CT scan was performed. The pre- and postoperative 3D CT scan reconstructions were superimposed to calculate the deviation between planned and postoperative inclination, retroversion, entry point, depth and rotation of the glenoid component placement. Additionally, a comparison between intra- and postoperative values was calculated. Outliers were defined as >10° inclination, >10° retroversion, >3 mm entry point.

RESULTS

The registration algorithm of the scapulae prior to the procedure was correctly completed for all cases. The deviations between planned and postoperative values were 1.0 ± 0.7° for inclination, 1.8 ± 1.3° for retroversion, 1.1± 0.4mm for entry point, 0.7 ± 0.6mm for depth, and 1.7 ± 1.6° for rotation. The deviation between intra- and postoperative values were 0.9±0.8° for inclination, 1.2±1.1° for retroversion, 0.6±0.5mm for depth, and 0.3±0.2° for rotation. There were no outliers between planned and postoperative parameters.

CONCLUSION

In this study, the use of a navigated AR system through a HMD for RSA led to low deviation between planned and postoperative values and between intra- and postoperative parameters.
Date Issued
2023-12
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Computer-assisted reverse shoulder arthroplasty augmented reality glenoid component head-mounted display navigated reverse shoulder arthroplasty smart glasses
Language(s)
en
Author(s)
Rojas, J Tomás
Jost, Bernhard
Zipeto, Claudio
Budassi, Piero
Zumstein, Matthias  
Universitätsklinik für Orthopädische Chirurgie und Traumatologie  
Additional Credits
Universitätsklinik für Orthopädische Chirurgie und Traumatologie  
Journal
Journal of shoulder and elbow surgery
Publisher
Elsevier
ISSN
1058-2746
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: da6d1d [14.09. 16:14]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify