  3. Systematic literature review on the benefit of patient protection shielding during medical X-ray imaging: Towards a discontinuation of the current practice.

Systematic literature review on the benefit of patient protection shielding during medical X-ray imaging: Towards a discontinuation of the current practice.

Details
Files
DOI
10.48350/164515
Publisher DOI
10.1016/j.ejmp.2021.12.016
PubMed ID
35030383
Abstract
PURPOSE

Patient shielding during medical X-ray imaging has been increasingly criticized in the last years due to growing evidence that it often provides minimal benefit and may even compromise image quality. In Europe, and as also shown in a short assessment in Switzerland, the use of patient shielding is inhomogeneous. The aim of this study was to systematically review recent literature in order to assess benefits and appraise disadvantages related to the routine use of patient shielding.

METHODS

To evaluate benefits and disadvantages related to the application of patient shielding in radiological procedures, a systematic literature review was performed for CT, radiography, mammography and fluoroscopy-guided medical X-ray imaging. In addition, reports from medical physics societies and authorities of different countries were considered in the evaluation.

RESULTS

The literature review revealed 479 papers and reports on the topic, from which 87 qualified for closer analysis. The review considered in- and out-of-plane patient shielding as well as shielding for pregnant and pediatric patients. Dose savings and other dose and non-dose related effects of patient shielding were considered in the evaluation.

CONCLUSIONS

Although patient shielding has been used in radiological practice for many years, its use is no longer undisputed. The evaluation of the systematic literature review of recent studies and reports shows that dose savings are rather minimal while significant dose- and non-dose-related detrimental effects are present. Consequently, the routine usage of patient protection shielding in medical X-ray imaging can be safely discontinued for all modalities and patient groups.
Date Issued
2022-02
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Patient shielding Radiation protection Radiology X-ray imaging
Language(s)
en
Author(s)
Samara, Eleni Theano
Saltybaeva, Natalia
Sans Merce, Marta
Gianolini, Stefano
Ith, Michael  
Universitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie  
Additional Credits
Universitätsinstitut für Diagnostische, Interventionelle und Pädiatrische Radiologie  
Journal
Physica medica
Publisher
Elsevier
ISSN
1724-191X
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify