• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Comparative biomechanical analysis of monocortical and bicortical polyaxial screw rod fixation in canine lumbar vertebral stabilization

Comparative biomechanical analysis of monocortical and bicortical polyaxial screw rod fixation in canine lumbar vertebral stabilization

Details
Files
DOI
10.48620/85397
Publisher DOI
10.3389/fvets.2024.1434251
Abstract
Objective
This study aims to evaluate the biomechanical properties of polyaxial screws-rod fixation (PSR) in stabilizing a single vertebral motion unit (VMU) fracture model and to compare the effectiveness of different stabilization techniques such as monocortical and bicortical.

Methods
A total of 12 thoracolumbar vertebral column specimens were harvested from canine cadavers. These specimens were divided into two groups based on the stabilization technique applied: a monocortical group and a bicortical group. Each group underwent biomechanical testing to assess flexion/extension and lateral bending motions. The range of motion (ROM), neutral zone (NZ), and stiffness were measured for each lumbar VMU in three conditions: intact, fractured with unilateral stabilization, and fractured with bilateral stabilization.

Results
In the 3-column fracture model, PSR was unable to restore the ROM of an intact spine in flexion/extension. In lateral bending, only bilateral PSR successfully approached the ROM of the intact spine. Notably, PSR failures were observed in four specimens when applied as monocortical and unilateral stabilization.

Conclusion
The findings indicate that even bilateral PSR does not fully restore the intact spine's ROM in canine fracture models, highlighting the need for further research to optimize stabilization techniques. The current study demonstrates that a single 3-column lumbar fracture model VMU cannot be adequately stabilized using PSR in a canine model, suggesting potential limitations in both monocortical and bicortical approaches.
Date Issued
2025-02-12
Publication Type
Article
Language(s)
en
Author(s)
Guevar, Julien  
Department of Clinical Veterinary Medicine, Small Animal Clinic, Surgery  
Department of Clinical Veterinary Medicine, Small Animal Clinic  
Department of Clinical Veterinary Medicine  
Voumard, Benjamin
Bergman, Robert
Precht, Maria Christina  orcid-logo
Department of Clinical Veterinary Medicine, Clinical Radiology  
Department of Clinical Veterinary Medicine  
Forterre, Franck  
Department of Clinical Veterinary Medicine, Small Animal Clinic, Surgery  
Small Animal Clinic  
Department of Clinical Veterinary Medicine  
Additional Credits
Department of Clinical Veterinary Medicine  
Department of Clinical Veterinary Medicine, Clinical Radiology  
Department of Clinical Veterinary Medicine, Small Animal Clinic, Surgery  
Department of Clinical Veterinary Medicine, Small Animal Clinic  
Small Animal Clinic  
Journal
Frontiers in Veterinary Science
Publisher
Frontiers Media
ISSN
2297-1769
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify