• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Dielectric elastomer Actuator-Based valveless pump as fontan failure assist device: Introduction and preliminary study.

Dielectric elastomer Actuator-Based valveless pump as fontan failure assist device: Introduction and preliminary study.

Details
Files
DOI
10.48350/194624
Publisher DOI
10.1093/icvts/ivae041
PubMed ID
38514398
Abstract
OBJECTIVES

Fontan failure refers to a condition in which the Fontan circulation, a surgical procedure used to treat certain congenital heart defects, becomes insufficient, leading to compromised cardiac function and potential complications. This in vitro study therefore investigates the feasibility of bladeless impedance-driven cavopulmonary assist device via dielectric elastomer actuator (DEA) as a means to address Fontan failure.

METHODS

A cavopulmonary assist device, constructed using DEA technologies and employing the impedance pump concept, is subjected to in vitro testing within a closed-loop setup. This study aims to assess the device's functionality and performance under controlled conditions, providing valuable insights into its potential application as a cavopulmonary assistive technology.

RESULTS

The DEA-based pump, measuring 50 mm in length and 30 mm in diameter, is capable of achieving substantial flow rates within a closed-loop setup, reaching up to 1.20 L/min at an activation frequency of 4 Hz. It also provides a broad range of working internal pressures (less than 10 mmHg to more than 20 mmHg). Lastly, the properties of the flow (direction, magnitude, etc) can be controlled by adjusting the input signal parameters (frequency, amplitude, etc).

CONCLUSIONS

In summary, the results suggests that the valveless impedance-driven pump utilizing DEA technology is promising in the context of cavopulmonary assist devices. Further research and development in this area may lead to innovative and potentially more effective solutions for assisting the right heart, ultimately benefiting patients with heart-related health issues overall, with a particular focus on those experiencing Fontan failure.
Date Issued
2024-03-29
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
500 Science > 570 Life sciences; biology
Subjects
Fontan failure cavopulmonary assist device congenital heart defect valveless pumping
Language(s)
en
Author(s)
Benouhiba, Amine
Walter, Armando
Jahren, Silje Ekroll  orcid-logo
ARTORG Center for Biomedical Engineering Research  
ARTORG Center for Biomedical Engineering Research - Cardiovascular Engineering  
Martinez, Thomas
Clavica, Francesco  orcid-logo
ARTORG Center - Cardiovascular Engineering (CVE)  
ARTORG Center for Biomedical Engineering Research - Urogenital Engineering  
Heinisch, Paul Philipp
Obrist, Dominik  orcid-logo
ARTORG Center for Biomedical Engineering Research - Cardiovascular Engineering  
Civet, Yoan
Perriard, Yves
Additional Credits
ARTORG Center for Biomedical Engineering Research - Urogenital Engineering  
ARTORG Center - Cardiovascular Engineering (CVE)  
ARTORG Center for Biomedical Engineering Research  
Journal
Interdisciplinary cardiovascular and thoracic surgery
Publisher
Oxford University Press
ISSN
2753-670X
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify