• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. You Can't Touch This: Touch-free Navigation Through Radiological Images

You Can't Touch This: Touch-free Navigation Through Radiological Images

Details
Publisher DOI
10.1177/1553350611425508
PubMed ID
22064490
Abstract
Keyboards, mice, and touch screens are a potential source of infection or contamination in operating rooms, intensive care units, and autopsy suites. The authors present a low-cost prototype of a system, which allows for touch-free control of a medical image viewer. This touch-free navigation system consists of a computer system (IMac, OS X 10.6 Apple, USA) with a medical image viewer (OsiriX, OsiriX foundation, Switzerland) and a depth camera (Kinect, Microsoft, USA). They implemented software that translates the data delivered by the camera and a voice recognition software into keyboard and mouse commands, which are then passed to OsiriX. In this feasibility study, the authors introduced 10 medical professionals to the system and asked them to re-create 12 images from a CT data set. They evaluated response times and usability of the system compared with standard mouse/keyboard control. Users felt comfortable with the system after approximately 10 minutes. Response time was 120 ms. Users required 1.4 times more time to re-create an image with gesture control. Users with OsiriX experience were significantly faster using the mouse/keyboard and faster than users without prior experience. They rated the system 3.4 out of 5 for ease of use in comparison to the mouse/keyboard. The touch-free, gesture-controlled system performs favorably and removes a potential vector for infection, protecting both patients and staff. Because the camera can be quickly and easily integrated into existing systems, requires no calibration, and is low cost, the barriers to using this technology are low.
Date Issued
2011
Publication Type
Article
Language(s)
en
Author(s)
Ebert, Lars Christian  
Institut für Rechtsmedizin, Forensische Medizin und Bildgebung  
Hatch, Gary  
Institut für Rechtsmedizin, Forensische Medizin und Bildgebung  
Ampanozi, Garyfalia  
Institut für Rechtsmedizin, Forensische Medizin und Bildgebung  
Thali, Michael  
Institut für Rechtsmedizin  
Ross, Steffen  
Institut für Rechtsmedizin  
Additional Credits
Institut für Rechtsmedizin  
Institut für Rechtsmedizin, Forensische Medizin und Bildgebung  
Journal
Surgical innovation
Publisher
Sage
ISSN
1553-3506
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify