  3. Leaflet Kinematics of Mechanical and Bioprosthetic Aortic Valve Prostheses.

Leaflet Kinematics of Mechanical and Bioprosthetic Aortic Valve Prostheses.

Details
Files
DOI
10.7892/boris.107666
Publisher DOI
10.1097/MAT.0000000000000687
PubMed ID
29045279
Abstract
The hemodynamic performance of artificial aortic valves (AVs) and the probability for structural valve deterioration can be linked to the valve kinematics. Comparability among different studies is limited because of variations in the experimental setups and physiologic boundary conditions. This study presents results of kinematic measurements of bioprosthetic and mechanical AVs that were tested in an identical experimental setting such that they can be directly compared with each other. The kinematics of AVs is typically presented in the form of the geometric orifice area and its temporal evolution. These parameters cannot capture asynchronous leaflet motion and out-of-plane leaflet velocity. In this work, each leaflet was tracked individually for a more detailed understanding of the leaflet kinematics, asynchronous leaflet motion, and leaflet tip velocities. A bioprosthetic valve, Edwards INTUITY (EINT), and two mechanical valves, Medtronic ADVANTAGE (MADV) and a Lapeyre-Triflo FURTIVA (TFUR), were tested in a compliant model of the aortic root in a physiologic flow loop. TFUR and MADV opened alike with maximum leaflet tip velocities of 0.77 and 0.66 m/s, respectively. The opening of EINT showed significantly higher local in-plane leaflet velocities of more than 2 m/s. EINT and TFUR exhibited similar early and slow closure. MADV closed significantly later with increased velocity. TFUR had a median maximum leaflet tip velocity of 0.39 m/s during valve closure and that of MADV was 0.83 m/s, whereas EINT exhibited a median maximum local in-plane leaflet velocity of 0.37 m/s. EINT experienced leaflet fluttering during systole with a flapping frequency of 36 Hz.
Date Issued
2017-10-18
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Author(s)
Vennemann, Bernhard Martin  
ARTORG - Cardiovascular Engineering (CVE)  
Rösgen, Thomas
Heinisch, Paul Philipp  
Universitätsklinik für Herz- und Gefässchirurgie  
Obrist, Dominik  orcid-logo
ARTORG - Cardiovascular Engineering (CVE)  
Additional Credits
ARTORG - Cardiovascular Engineering (CVE)  
Universitätsklinik für Herz- und Gefässchirurgie  
Journal
ASAIO journal
Publisher
Lippincott
ISSN
1058-2916
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: da6d1d [14.09. 16:14]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify