Overcoming data scarcity in life-threatening arrhythmia detection through transfer learning.
Publisher DOI
PubMed ID
40595433
Abstract
Background
Life-threatening arrhythmias (LTAs) are a leading cause of death worldwide. Enhancing LTA detection in wearable monitoring systems is of great importance. One of the main challenges in building robust LTA detection algorithms is the limited availability of labeled LTA data.Methods
We introduce an effective deep-learning algorithm for detecting LTAs from single-lead ECGs in out-of-hospital cardiac arrest applications. We address the data-scarcity issue by applying a transfer learning approach. The deep-learning model is pre-trained on a massive dataset (72'952 recordings) for rhythm classification and then fine-tuned on the target dataset with LTA events (102 recordings).Results
Our model achieves a sensitivity of 92.68% and a specificity of 99.48%, with a granularity of 1.28 seconds, in detecting LTAs. Additionally, a confidence estimation procedure is introduced to enable emergency service pre-alerts in case of low-confidence detections.Conclusions
Our transfer learning based approach has the potential to significantly mitigate the impact of data scarcity, advancing LTA detection in wearable monitoring systems, and supporting rapid, life-saving interventions in out-of-hospital cardiac arrest emergencies.Life-threatening arrhythmias (LTAs) are critical cardiac conditions that can lead to sudden cardiac death, frequently occurring outside of clinical settings. Early detection of these events using wearable devices has the potential to significantly increase survival rates. However, developing reliable automated detection systems remains challenging due to the limited data availability on these rare events. In this study, we propose a deep-learning model that leverages transfer learning: it initially learns from a large dataset of general cardiac signals and subsequently adapts to a smaller dataset specific to LTA cases. The model demonstrates high accuracy in identifying LTAs and provides a confidence measure for each detection. This approach may facilitate timely emergency responses and improve outcomes in real-world scenarios involving sudden cardiac arrest.
Life-threatening arrhythmias (LTAs) are a leading cause of death worldwide. Enhancing LTA detection in wearable monitoring systems is of great importance. One of the main challenges in building robust LTA detection algorithms is the limited availability of labeled LTA data.Methods
We introduce an effective deep-learning algorithm for detecting LTAs from single-lead ECGs in out-of-hospital cardiac arrest applications. We address the data-scarcity issue by applying a transfer learning approach. The deep-learning model is pre-trained on a massive dataset (72'952 recordings) for rhythm classification and then fine-tuned on the target dataset with LTA events (102 recordings).Results
Our model achieves a sensitivity of 92.68% and a specificity of 99.48%, with a granularity of 1.28 seconds, in detecting LTAs. Additionally, a confidence estimation procedure is introduced to enable emergency service pre-alerts in case of low-confidence detections.Conclusions
Our transfer learning based approach has the potential to significantly mitigate the impact of data scarcity, advancing LTA detection in wearable monitoring systems, and supporting rapid, life-saving interventions in out-of-hospital cardiac arrest emergencies.Life-threatening arrhythmias (LTAs) are critical cardiac conditions that can lead to sudden cardiac death, frequently occurring outside of clinical settings. Early detection of these events using wearable devices has the potential to significantly increase survival rates. However, developing reliable automated detection systems remains challenging due to the limited data availability on these rare events. In this study, we propose a deep-learning model that leverages transfer learning: it initially learns from a large dataset of general cardiac signals and subsequently adapts to a smaller dataset specific to LTA cases. The model demonstrates high accuracy in identifying LTAs and provides a confidence measure for each detection. This approach may facilitate timely emergency responses and improve outcomes in real-world scenarios involving sudden cardiac arrest.
Date Issued
2025-07-01
Publication Type
Article
Subject(s)
Language(s)
en
Author(s)
Zanchi, Beatrice | |
Wand, Michael | |
Conte, Giulio |
Additional Credits
Journal
communications medicine
Publisher
Nature Research
ISSN
2730-664X
Access(Rights)