  3. Transcarotid aortic valve-in-valve implantation for degenerated stentless aortic root conduits with severe regurgitation: a case series

Transcarotid aortic valve-in-valve implantation for degenerated stentless aortic root conduits with severe regurgitation: a case series

Details
Files
DOI
10.7892/boris.74083
Publisher DOI
10.1093/icvts/ivv053
PubMed ID
25776924
Abstract
OBJECTIVES

Transcatheter aortic valve implantation (TAVI) is routinely performed via the transfemoral and the transapical route. Subclavian and direct aortic access are described alternatives for TAVI. Recently, the transcarotid approach has been shown to be feasible among patients with limited vascular access and severe native aortic valve stenosis. We aim to investigate the feasibility of transcatheter aortic valve-in-valve implantation via the transcarotid access in patients with severe aortic regurgitation due to degenerated stentless Shelhigh conduits using the 29 mm Medtronic CoreValve bioprosthesis.

METHODS

Three patients with complex vascular anatomy undergoing transcatheter valve-in-valve implantation via the transcarotid route were enrolled in the study. The procedure was performed under general anaesthesia using surgical cut-down to facilitate vascular access. Immediate procedural results as well as echocardiographic and clinical outcomes after 30 days and 6 months of the follow-up were recorded and analysed.

RESULTS

All three patients underwent unproblematic TAVI and experienced dramatic improvement of symptoms. Mean transvalvular gradient was 3, 6 and 11 mmHg, respectively. Effective orifice area ranged between 1.7 and 2.2 cm(2). Only mild paravalvular regurgitation was detected by echocardiography after 30 days of the follow-up.

CONCLUSIONS

The transcarotid approach can be safely performed for valve-in-valve procedures using the Medtronic CoreValve in patients with limited vascular access. It enables accurate positioning and implantation of the prosthesis.
Date Issued
2015-06
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Aortic regurgitation Transcatheter aortic valve implantation Valve-in-valve Valvular heart disease
Language(s)
en
Author(s)
Huber, Christoph  
Universitätsklinik für Herz- und Gefässchirurgie  
Praz, Fabien Daniel  
Universitätsklinik für Kardiologie  
O'Sullivan, Crochan John  
Universitätsklinik für Kardiologie  
Langhammer, Bettina  
Universitätsklinik für Herz- und Gefässchirurgie  
Glökler, Steffen  
Universitätsklinik für Kardiologie  
Stortecky, Stefan  
Universitätsklinik für Kardiologie  
Von Allmen, Regula Sybille  
Universitätsklinik für Herz- und Gefässchirurgie  
Meier, Bernhard  
Universitätsklinik für Kardiologie  
Carrel, Thierry  
Universitätsklinik für Herz- und Gefässchirurgie  
Englberger, Lars  
Universitätsklinik für Herz- und Gefässchirurgie  
Windecker, Stephan  
Universitätsklinik für Kardiologie  
Wenaweser, Peter Martin  
Universitätsklinik für Kardiologie  
Additional Credits
Universitätsklinik für Kardiologie  
Universitätsklinik für Herz- und Gefässchirurgie  
Journal
Interactive cardiovascular and thoracic surgery
Publisher
Oxford University Press
ISSN
1569-9293
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify