• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Sedline® Miscalculation of Depth of Anaesthesia Variables in Two Pigs Due to Electrocardiographic Signal Contamination.

Sedline® Miscalculation of Depth of Anaesthesia Variables in Two Pigs Due to Electrocardiographic Signal Contamination.

Details
Files
DOI
10.48350/186198
Publisher DOI
10.3390/ani13172699
PubMed ID
37684963
Abstract
Two young (11-week-old) pigs underwent sole propofol anaesthesia as part of an experimental study. The depth of anaesthesia was evaluated both clinically and using the electroencephalography(EEG)-based monitor Sedline; in particular, the patient state index, suppression ratio, raw EEG traces, and its spectrogram were assessed. Physiological parameters and electrocardiographic activity were continuously monitored. In one pig (Case 1), during the administration of high doses of propofol, the Sedline-generated variables suddenly indicated an increased EEG activity while this was not confirmed by observation of either the raw EEG or its spectrogram. In the second pig (Case 2), a similar event was recorded during euthanasia with systemic pentobarbital. Both events happened while the EEG activity was isoelectric except for signal interferences and synchronous in rhythm and shape with the electrocardiographic activity. The suggestion of increased brain activity based on the interpretation of the Sedline variables was suspected wrong; most probably due to electrocardiographic interferences. In pigs, the patient state index and suppression ratio, as calculated by the Sedline monitor, could be influenced by the electrocardiographic activity contaminating the EEG trace, especially during otherwise isoelectric periods (strong EEG depression). Visual interpretation of the raw EEG and of the spectrogram remains necessary to identify such artefacts.
Date Issued
2023-08-23
Publication Type
Article
Subject(s)
600 Technology > 630 Agriculture
Subjects
Sedline depth of anaesthesia electrocardiogram electroencephalogram interference patient state index pig signal contamination suppression ratio
Language(s)
en
Author(s)
Mirra, Alessandro  orcid-logo
Departement für klinische Veterinärmedizin - Anästhesiologie  
Hight, Darren Fletcher  orcid-logo
Universitätsklinik für Anästhesiologie und Schmerztherapie  
Kovacevic, Alan  
Departement für klinische Veterinärmedizin, Kleintierklinik  
Levionnois, Olivier  orcid-logo
Departement für klinische Veterinärmedizin (DKV) Universität Bern  
Departement für klinische Veterinärmedizin - Anästhesiologie  
Additional Credits
Universitätsklinik für Anästhesiologie und Schmerztherapie  
Departement für klinische Veterinärmedizin, Kleintierklinik  
Departement für klinische Veterinärmedizin (DKV) Universität Bern  
Departement für klinische Veterinärmedizin - Anästhesiologie  
Journal
Animals
Publisher
MDPI
ISSN
2076-2615
Access(Rights)
Unknown
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify