  3. The influence of cardiac arrhythmias on the detection of heartbeats in the photoplethysmogram: benchmarking open-source algorithms.
 

The influence of cardiac arrhythmias on the detection of heartbeats in the photoplethysmogram: benchmarking open-source algorithms.

Options
  • Details
  • Files
BORIS DOI
10.48350/192109
Publisher DOI
10.1088/1361-6579/ad2216
PubMed ID
38266291
Description
Cardiac arrhythmias are a leading cause of mortality worldwide. Wearable devices based on photoplethysmography give the opportunity to screen large populations, hence allowing for an earlier detection of pathological rhythms that might reduce the risks of complications and medical costs. While most of beat detection algorithms have been evaluated on normal sinus rhythm or atrial fibrillation recordings, the performance of these algorithms in patients with other cardiac arrhythmias, such as ventricular tachycardia or bigeminy, remain unknown to date. The PPG-beats open-source framework, developed by Charlton and colleagues, evaluates the performance of the beat detectors named QPPG, MSPTD and ABD among others. We applied the PPG-beats framework on two newly acquired datasets, one containing seven different types of cardiac arrhythmia in hospital settings, and another dataset including two cardiac arrhythmias in ambulatory settings. In a clinical setting, the QPPG beat detector performed best on atrial fibrillation (with a median F1 score of 94.4%), atrial flutter (95.2%), atrial tachycardia (87.0%), sinus rhythm (97.7%), ventricular tachycardia (83.9%) and was ranked 2nd for bigeminy (75.7%) behind ABD detector (76.1%). In an ambulatory setting, the MSPTD beat detector performed best on normal sinus rhythm (94.6%), and the QPPG detector on atrial fibrillation (91.6%) and bigeminy (80.0%). Overall, the PPG beat detectors QPPG, MSPTD and ABD consistently stand out from other detectors with high performances. However, the detection of beats from wrist-PPG signals is compromised in presence of bigeminy or ventricular tachycardia.
Date of Publication
2024-02-14
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Keyword(s)
Atrial Fibrillation Beat Detection Bigeminy Cardiac Arrhythmias Heartbeat Photoplethysmography Ventricular Tachycardia
Language(s)
en
Contributor(s)
Jeanningros, Loïc
Le Bloa, Mathieu
Teres, Cheryl
Herrera Siklody, Claudia
Porretta, Alessandra
Pascale, Patrizio
Luca, Adrian
Solana Muñoz, Jorge
Domenichini, Giulia
Meister, Théo Arthur Perceval
Universitätsklinik für Kardiologie
Soria Maldonado, Rodrigo
Universitätsklinik für Kardiologie
Tanner, Hildegard
Universitätsklinik für Kardiologie
Vesin, Jean-Marc
Thiran, Jean-Philippe
Lemay, Mathieu
Rexhaj, Emrush
Universitätsklinik für Kardiologie
Pruvot, Etienne
Braun, Fabian
Additional Credits
Universitätsklinik für Kardiologie
Series
Physiological measurement
Publisher
IOP Publishing
ISSN
1361-6579
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: dd892c [ 9.04. 8:30]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo