• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. In vivo bisphenol-a release from dental pit and fissure sealants: a systematic review

In vivo bisphenol-a release from dental pit and fissure sealants: a systematic review

Details
Files
DOI
10.7892/boris.40048
Publisher DOI
10.1016/j.jdent.2013.04.012
PubMed ID
23643847
Abstract
OBJECTIVE

To search the literature and assess the short- and long-term release of bisphenol-A (BPA) in human tissues after treatment with dental sealants.

DATA

Two review authors performed data extraction independently and in duplicate using data collection forms. Disagreements were resolved by discussion with an arbiter.

SOURCES

Electronic database searches of published and unpublished literature were performed. The following electronic databases with no language and publication date restrictions were searched: MEDLINE (via Ovid and Pubmed), EMBASE (via ovid), Cochrane Trials Register and CENTRAL. The reference lists of all eligible studies were hand-searched.

STUDY SELECTION

In the absence of RCTs, six interventional and two observational studies, examining in vivo BPA release in human salivary, blood and urinary samples, were included. Due to the heterogeneity in methodology and reporting, the main synthesis of the results was qualitative. The quantitative synthesis based on the weighted Z-test could only include two studies. BPA levels identified in saliva ranged from traces below the method's detection limit to 30 μg/ml. In urine, BPA quantities spanned from 0.17 mg/g to 45.4 mg/g. BPA was not traced in any blood sample at any point of time in the relevant studies. The quantitative analysis showed evidence of BPA release one hour after sealant placement compared to the amount traced before restoration (Stouffer's z trend: <0.001).

CONCLUSIONS

The available evidence on this topic derived from studies that represent a moderate level of evidence. Nevertheless, the available evidence supports that BPA is released in saliva after sealant placement.

CLINICAL SIGNIFICANCE

From the qualititative and quantitative synthesis of studies, it is reasonable to conclude that BPA is released after placement of some dental pit and fissure sealants in the oral cavity. The biggest quantities are detected in saliva immediately after or one hour after their placement.
Date Issued
2013-08
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Bisphenol A
•
Dental sealants
•
In vivo
Language(s)
en
Author(s)
Kloukos, Dimitrios  orcid-logo
Zahnmedizinische Kliniken (ZMK)  
Pandis, Nikolaos  
Zahnmedizinische Kliniken, Klinik für Kieferorthopädie  
Eliades, Theodore  
Zahnmedizinische Kliniken, Klinik für Kieferorthopädie  
Additional Credits
Zahnmedizinische Kliniken (ZMK)  
Zahnmedizinische Kliniken, Klinik für Kieferorthopädie  
Journal
Journal of dentistry
Publisher
Elsevier Science
ISSN
0300-5712
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify