• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Does long-term intraoral service affect the mechanical properties and elemental composition of multistranded wires of lingual fixed retainers?

Does long-term intraoral service affect the mechanical properties and elemental composition of multistranded wires of lingual fixed retainers?

Details
Files
DOI
10.7892/boris.126489
Publisher DOI
10.1093/ejo/cjx045
PubMed ID
28633359
Abstract
Purpose

The aim of this study was to evaluate the elemental and mechanical alterations of stainless steel (SS) multistranded orthodontic wires used in fixed retention after intraoral ageing.

Materials and Methods

Two types of 0.022-inch, seven-stranded wires, Lingual Retainer Wire (LRW) and Tru-Chrome (TCH), from the same manufacturer (Rocky Mountain Orthodontics, Denver, Colo, USA) were tested. Thirty-three samples from LRW group and thirty-seven from TCH were collected, whereas three unused wires from each package were used as controls. The median ageing time for LRW was 7.4 years and 8.4 for TCH. All samples were subjected to scanning electron microscope/X-ray energy dispersive spectroscopy analysis. Three spectra were taken from the surface of each wire and then all samples were used for the assessment of Martens hardness, indentation modulus (EIT), and elastic index (ηIT) with the instrumented indentation testing method (IIT). The intraoral ageing time was statistically compared between the two groups by Mann-Whitney rank sum test and the compositional and mechanical properties were compared by unpaired t-test. The Spearman correlation between elemental content and ageing time was carried out for all elements (a = 0.05).

Results

No significant differences were found for both the elemental content and for the mechanical properties between the wires tested. Spearman analysis revealed no correlation between elemental content and intraoral time while two groups share statistically equal intraoral ageing times (P > 0.05).

Conclusions

Both wires seemed to maintain their mechanical and elemental integrity within a period of 14-year intraoral exposure, whereas no measurable ionic release could be identified.
Date Issued
2018-04-06
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
en
Author(s)
Zinelis, Spiros
Pandis, Nikolaos  
Zahnmedizinische Kliniken, Klinik für Kieferorthopädie  
Al Jabbari, Youssef S
Eliades, George
Eliades, Theodore
Additional Credits
Zahnmedizinische Kliniken, Klinik für Kieferorthopädie  
Journal
European journal of orthodontics
Publisher
Oxford University Press
ISSN
0141-5387
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify