Effect of implant location and operator on the accuracy of implant scans using a combined healing abutment-scan body system.

Details
Files
DOI
10.48350/161764
Publisher DOI
10.1016/j.jdent.2021.103855
PubMed ID
34688778
Abstract
OBJECTIVES

To investigate the effect of implant location and operator on the accuracy of implant scans conducted with a combined healing abutment-scan body (CHA-SB) system.

MATERIAL AND METHODS

A CHA-SB system was fixed on implants at left central incisor, first premolar, and first molar sites in a dentate maxillary model. An industrial optical scanner (ATOS Core 80) was utilized to scan and generate a reference model (RM). The model was scanned by three operators (n = 8) using an intraoral scanner (TRIOS 3). A software (GOM Inspect) was used to superimpose IOS test scans over RM and calculations (distance and angular deviations) were carried out to evaluate the accuracy of the scans. Data were compared with a 2-way ANOVA and Tukey HSD tests were employed to resolve significant interactions for trueness and precision (α = .05).

RESULTS

Implant location affected the trueness (P ≤ .001) and the precision (P ≤ .020) (distance and angular deviations). The scans of the implant at the central incisor site had the highest trueness (distance and angular deviations) (P ≤ .016). The scans of the implant at molar site had the lowest precision (distance deviation data) (P ≤ .012). The scans of the implant at premolar site had lower precision (angular deviation data) than the scans of the implant at central incisor site (P = .016). Operators' effect on the accuracy of scans was not significant (P ≥  .051).

CONCLUSION

Implant location affected the scan accuracy of the combined healing abutment-scan body system. The scans of the implant at central incisor site had high trueness. The posterior the implant location, the lower was the precision of the scans. The accuracy of scans of different operators was similar.

CLINICAL SIGNIFICANCE

Higher deviations found in scans of posterior maxilla compared with those in the anterior region may require increased chairside adjustments when crowns are to be fabricated using the scans of the tested healing abutment-scan body system. However, clinical studies are necessary to corroborate the findings.
Date Issued
2021-12
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Accuracy Healing abutment-scan body Intraoral scanner Trueness
Language(s)
en
Author(s)
Atalay, Sevda
Cakmak, Gülce  
Zahnmedizinische Kliniken (ZMK)  
Dönmez, Mustafa-Borga  
Zahnmedizinische Kliniken (ZMK)  
Yilmaz, Hakan
Kökat, Ali Murat
Yilmaz, Burak  
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie  
Additional Credits
Zahnmedizinische Kliniken (ZMK)  
Zahnmedizinische Kliniken, Klinik für Rekonstruktive Zahnmedizin und Gerodontologie  
Journal
Journal of dentistry
Publisher
Elsevier Science
ISSN
0300-5712
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify