Profile of Instrumentation Laboratory's HemosIL® AcuStar HIT-Ab(PF4-H) assay for diagnosis of heparin-induced thrombocytopenia.

Details
Files
DOI
10.7892/boris.100068
Publisher DOI
10.1080/14737159.2017.1304213
PubMed ID
28271738
Abstract
INTRODUCTION

Immunoassays play an essential role in the diagnosis of heparin-induced thrombocytopenia (HIT). The objective of this article is to review HemosIL® AcuStar HIT-Ab(PF4-H) (Instrumentation Laboratory, Bedford, MA, USA), a new chemiluminescent immunoassay for HIT. Areas covered: The authors searched the published literature for evaluation studies of HemosIL® AcuStar HIT-Ab(PF4-H) and sought information from the manufacturer. In this paper, the authors discuss the analytical principle and technical aspects of the assay; describe its diagnostic performance in validation studies; report on its reproducibility, cost-effectiveness, and regulatory status; and discuss the implications of the assay on clinical practice and means of integrating it in diagnostic pathways. HemosIL® AcuStar HIT-Ab(PF4-H) is compared with other rapid assays and widely used enzyme-linked immunoassays for the diagnosis of HIT. Expert commentary: HemosIL® AcuStar HIT-Ab(PF4-H) is automatable, can be performed 24 h per day, offers a rapid turnaround time, and appears to have favorable diagnostic accuracy, particularly at thresholds above that listed in the label. These advantages could lead to improved patient outcomes through rapid provision of results at the point of care, enhancing the accuracy of initial diagnosis.
Date Issued
2017-05
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Diagnosis chemiluminescence heparin heparin-induced thrombocytopenia immunoassay
Language(s)
en
Author(s)
Nagler, Michael  
Departement Klinische Forschung, Forschungsgruppe Hämatologie (Erwachsene)  
Universitätsklinik für Hämatologie und Hämatologisches Zentrallabor  
Cuker, Adam
Additional Credits
Departement Klinische Forschung, Forschungsgruppe Hämatologie (Erwachsene)  
Universitätsklinik für Hämatologie und Hämatologisches Zentrallabor  
Journal
Expert review of molecular diagnostics
Publisher
Expert Reviews
ISSN
1473-7159
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify