• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. On the role of aortic valve architecture for physiological hemodynamics and valve replacement, Part II: Spectral analysis and anisotropy.

On the role of aortic valve architecture for physiological hemodynamics and valve replacement, Part II: Spectral analysis and anisotropy.

Details
Files
DOI
10.48350/196881
Publisher DOI
10.1016/j.compbiomed.2024.108552
PubMed ID
38754219
Abstract
Severe aortic valve stenosis can lead to heart failure and aortic valve replacement (AVR) is the primary treatment. However, increasing prevalence of aortic stenosis cases reveal limitations in current replacement options, necessitating improved prosthetic aortic valves. We investigate flow disturbances downstream of severe aortic stenosis and two bioprosthetic aortic valve (BioAV) designs using advanced energy-based analyses. Three-dimensional high-fidelity fluid-structure interaction simulations have been conducted and a dedicated and novel spectral analysis has been developed to characterise the kinetic energy (KE) carried by eddies in the wavenumber space. In addition, new field quantities, i.e. modal KE anisotropy intensity as well as normalised helicity intensity, are introduced. Spectral analysis shows kinetic energy (KE) decay variations, with the stenotic case aligning with Kolmogorov's theory, while BioAV cases differing. We explore the impact of flow helicity on KE transfer and decay in BioAVs. Probability distributions of modal KE anisotropy unveil flow asymmetries in the stenotic and one BioAV cases. Moreover, an inverse correlation between temporally averaged modal KE anisotropy and normalised instantaneous helicity intensity is noted, with the coefficient of determination varying among the valve configurations. Leaflet dynamics analysis highlights a stronger correlation between flow and biomechanical KE anisotropy in one BioAV due to higher leaflet displacement magnitude. These findings emphasise the role of valve architecture in aortic turbulence as well as its importance for BioAV performance and energy-based design enhancement.
Date Issued
2024-05-03
Publication Type
Article
Subject(s)
500 Science > 530 Physics
600 Technology > 610 Medicine & health
600 Technology > 620 Engineering
Subjects
Aortic stenosis Bioprosthetic aortic valve replacement Flow turbulence Helicity Kinetic energy anisotropy Spectral analysis
Language(s)
en
Author(s)
Corso, Pascal  orcid-logo
ARTORG Center for Biomedical Engineering Research - Cardiovascular Engineering  
Obrist, Dominik  orcid-logo
ARTORG Center for Biomedical Engineering Research - Cardiovascular Engineering  
Additional Credits
ARTORG Center for Biomedical Engineering Research - Cardiovascular Engineering  
Journal
Computers in biology and medicine
Publisher
Elsevier
ISSN
1879-0534
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify