  3. Amplatzer left atrial appendage closure: Single versus combined procedures.

Amplatzer left atrial appendage closure: Single versus combined procedures.

Details
Files
DOI
10.48350/163237
Publisher DOI
10.1002/ccd.29271
PubMed ID
32930492
Abstract
OBJECTIVES

This study compares procedural and late clinical outcomes of left atrial appendage closure (LAAC) with Amplatzer devices as a single versus a combined procedure with other structural or coronary interventions.

BACKGROUND

Multiple cardiac conditions are frequent among elderly patients and invite simultaneous treatment to ensure a favorable patient outcomes.

METHODS

559 consecutive patients (73.3 ± 11.1 years) underwent LAAC with Amplatzer devices at two centres (Bern and Zurich university hospitals, Switzerland) either as a single procedure or combined with other interventions. The primary safety endpoint was a composite of major peri-procedural complications and major bleeding at follow-up, the primary efficacy endpoint included stroke, systemic embolism, and cardiovascular/unexplained death. All event rates are reported per 100 patient-years.

RESULTS

In 263 single and 296 combined procedures with percutaneous coronary interventions (47.6%), closure of an atrial septal defect (8.4%) or a patent foramen ovale (36.5%), transcatheter aortic valve implantation (10.1%), mitral clipping (4.1%), atrial fibrillation ablation (8.8%), or another procedure (3.0%) were analyzed. Device success (96.6% [single] vs. 99.0% [combined], p = .08) did not differ between the groups. After a mean follow-up of 2.6 ± 1.5 vs. 2.5 ± 1.5 years and a total of 1,422 patient-years, the primary efficacy (40/677, 5.9% [single] vs. 37/745, 5.0% [combined]; HR, 1.2, 95% CI, 0.8-1.9, p = .44), as well as the primary safety endpoint (25/677, 3.7% vs 28/745, 3.8%; HR, 1.0, 95% CI, 0.6-1.8, p = .89) were comparable.

CONCLUSIONS

LAAC with Amplatzer devices combined with structural, coronary, and electrophysiological procedures offers procedural feasibility and safety, as well as long-term efficacy.
Date Issued
2021-06-01
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Amplatzer atrial fibrillation combined left atrial appendage closure stroke
Language(s)
en
Author(s)
Kleinecke, Caroline
Buffle, Eric Jacques  
Universitätsklinik für Kardiologie  
Link, Juergen
Häner, Jonas
Sedaghat, Alexander
Galea, Roberto  
Universitätsklinik für Kardiologie  
Streit, Samuel R
Windecker, Stephan  
Universitätsklinik für Kardiologie  
Meier, Bernhard
Gloekler, Steffen
Additional Credits
Universitätsklinik für Kardiologie  
Journal
Catheterization and cardiovascular interventions
Publisher
Wiley-Blackwell
ISSN
1522-1946
Access(Rights)
restricted
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify