• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Detecting circulating antibodies by controlled surface modification with specific target proteins: Application to malaria.

Detecting circulating antibodies by controlled surface modification with specific target proteins: Application to malaria.

Details
Files
DOI
10.7892/boris.110615
Publisher DOI
10.1016/j.bios.2017.01.031
PubMed ID
28157657
Abstract
Sensitive detection of specific antibodies by biosensors has become of major importance for monitoring and controlling epidemics. Here we report a development of a biosensor able to specifically measure antibodies in a drop of unmodified blood serum. Within minutes, the detection system measures presence of antibodies against Plasmodium vivax, a causing agent for malaria. The biosensor consists of a layer of carbon nanotubes (CNTs) which were casted on a carbon working electrode area of a three-electrode system and oxidized. An amine layer was produced next by modifying the surface with EDAC/NHS followed by reaction with a diamine compound. Finally, the protein fragments derived from P. vivax containing well-known antigen sequences were casted on this layer and bound through electrostatic interactions, involving hydrogen and ionic bonding. All these chemical changes occurring at the carbon surface along the biosensor assembly were followed and confirmed by Fourier Transformed Infrared s pectrometry (FTIR) and Raman spectroscopy. The presence of antibodies in serum was detected by monitoring the electrical properties of the layer, making use of cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV), against a standard iron probe. Overall, the charge-transfer resistance decreased after antibody binding, because there was an additional amount of protein bound to the surface. This hindered the access of the iron redox probe to the conductive support at the electrode surface. Electrical changes could be measured at antibody concentration as low as ~6-50pg/L (concentrations in the range of 10-15M) and as high as ~70μg/L. Specific measurement with low background was even possible in undiluted serum. Hence, this novel biosensor allows assessing serum antibody levels in real time and in un-manipulated serum samples on-site where needed.
Date Issued
2017-05-15
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
Antibodies Biosensor Electrochemical measurements Immune response detection Malaria
Language(s)
en
Author(s)
Cardoso, Ana R
Cabral-Miranda, Gustavo
Reyes-Sandoval, Arturo
Bachmann, Martin  
Universitätsklinik für Rheumatologie, Immunologie und Allergologie  
Sales, M Goreti F
Additional Credits
Universitätsklinik für Rheumatologie, Immunologie und Allergologie  
Journal
Biosensors & bioelectronics
Publisher
Elsevier
ISSN
0956-5663
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify