• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Transesophageal echocardiography in cryptogenic stroke and patent foramen ovale: analysis of putative high-risk features from the risk of paradoxical embolism database

Transesophageal echocardiography in cryptogenic stroke and patent foramen ovale: analysis of putative high-risk features from the risk of paradoxical embolism database

Details
Files
DOI
10.7892/boris.44966
Publisher DOI
10.1161/CIRCIMAGING.113.000807
PubMed ID
24214884
Abstract
BACKGROUND

Patent foramen ovale (PFO) is associated with cryptogenic stroke (CS), although the pathogenicity of a discovered PFO in the setting of CS is typically unclear. Transesophageal echocardiography features such as PFO size, associated hypermobile septum, and presence of a right-to-left shunt at rest have all been proposed as markers of risk. The association of these transesophageal echocardiography features with other markers of pathogenicity has not been examined.

METHODS AND RESULTS

We used a recently derived score based on clinical and neuroimaging features to stratify patients with PFO and CS by the probability that their stroke is PFO-attributable. We examined whether high-risk transesophageal echocardiography features are seen more frequently in patients more likely to have had a PFO-attributable stroke (n=637) compared with those less likely to have a PFO-attributable stroke (n=657). Large physiologic shunt size was not more frequently seen among those with probable PFO-attributable strokes (odds ratio [OR], 0.92; P=0.53). The presence of neither a hypermobile septum nor a right-to-left shunt at rest was detected more often in those with a probable PFO-attributable stroke (OR, 0.80; P=0.45; OR, 1.15; P=0.11, respectively).

CONCLUSIONS

We found no evidence that the proposed transesophageal echocardiography risk markers of large PFO size, hypermobile septum, and presence of right-to-left shunt at rest are associated with clinical features suggesting that a CS is PFO-attributable. Additional tools to describe PFOs may be useful in helping to determine whether an observed PFO is incidental or pathogenically related to CS.
Date Issued
2014-01
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
cardiovascular imaging cerebrovascular disease/stroke congenital heart disease echocardiography foramen ovale
•
patent risk factor
Language(s)
en
Author(s)
Wessler, Benjamin S.
Thaler, David E.
Ruthazer, Robin
Weimar, Christian
Di Tullio, Marco R.
Elkind, Mitchell S. V.
Homma, Shunichi
Lutz, Jennifer S.
Mas, Jean-Louis
Mattle, Heinrich  
Universitätsklinik für Neurologie  
Meier, Bernhard  
Universitätsklinik für Kardiologie  
Nedeltchev, Krassen  
Universitätsklinik für Neurologie  
Papetti, Federica
Di Angelantonio, Emanuele
Reisman, Mark
Serena, Joaquín
Kent, David M.
Additional Credits
Universitätsklinik für Kardiologie  
Universitätsklinik für Neurologie  
Journal
Circulation. Cardiovascular Imaging
Publisher
Lippincott Williams & Wilkins
ISSN
1942-0080
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify