  3. Tissue properties of the human vertebral body sub-structures evaluated by means of microindentation

Tissue properties of the human vertebral body sub-structures evaluated by means of microindentation

Details
Publisher DOI
10.1016/j.jmbbm.2013.04.020
Abstract
Purpose

The better understanding of vertebral mechanical properties can help to improve the diagnosis of vertebral fractures. As the bone mechanical competence depends not only from bone mineral density (BMD) but also from bone quality, the goal of the present study was to investigate the anisotropic indentation moduli of the different sub-structures of the healthy human vertebral body and spondylophytes by means of microindentation.

Methods

Six human vertebral bodies and five osteophytes (spondylophytes) were collected and prepared for microindentation test. In particular, indentations were performed on bone structural units of the cortical shell (along axial, circumferential and radial directions), of the endplates (along the anterio-posterior and lateral directions), of the trabecular bone (along the axial and transverse directions) and of the spondylophytes (along the axial direction). A total of 3164 indentations down to a maximum depth of 2.5 µm were performed and the indentation modulus was computed for each measurement.

Results

The cortical shell showed an orthotropic behavior (indentation modulus, Ei, higher if measured along the axial direction, 14.6±2.8 GPa, compared to the circumferential one, 12.3±3.5 GPa, and radial one, 8.3±3.1 GPa). Moreover, the cortical endplates (similar Ei along the antero-posterior, 13.0±2.9 GPa, and along the lateral, 12.0±3.0 GPa, directions) and the trabecular bone (Ei= 13.7±3.4 GPa along the axial direction versus Ei=10.9±3.7 GPa along the transverse one) showed transversal isotropy behavior. Furthermore, the spondylophytes showed the lower mechanical properties measured along the axial direction (Ei=10.5±3.3 GPa).

Conclusions

The original results presented in this study improve our understanding of vertebral biomechanics and can be helpful to define the material properties of the vertebral substructures in computational models such as FE analysis.
Date Issued
2013-09
Publication Type
Article
Subject(s)
500 Science > 570 Life sciences; biology
600 Technology > 610 Medicine & health
600 Technology > 620 Engineering
Language(s)
en
Author(s)
Dall'Ara, E.
Karl, C.
Mazza, G.
Franzoso, G.
Vena, P.
Pretterklieber, M.
Pahr, D.
Zysset, Philippe  orcid-logo
Institut für chirurgische Technologien und Biomechanik (ISTB)  
Additional Credits
Institut für chirurgische Technologien und Biomechanik (ISTB)  
Journal
Journal of the mechanical behavior of biomedical materials
Publisher
Elsevier
ISSN
1751-6161
Access(Rights)
metadata.only
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: c618d0 [ 2.10. 13:10]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify