• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Radialer externer Fixateur zur geschlossenen Behandlung problematischer suprakondylärer Humerusfrakturen Typ III und IV bei Kindern und Jugendlichen

Radialer externer Fixateur zur geschlossenen Behandlung problematischer suprakondylärer Humerusfrakturen Typ III und IV bei Kindern und Jugendlichen

Radial external fixator for closed treatment of type III and IV supracondylar humerus fractures in children. A new surgical technique

Details
Files
DOI
10.7892/boris.62692
Publisher DOI
10.1007/s00064-013-0291-y
PubMed ID
24553691
Abstract
Operationsziel

Geschlossene, anatomische Reposition und sichere Fixation von problematischen suprakondylären Typ-III- und Typ-IV-Humerusfrakturen, die mit den herkömmlichen Operationsmethoden nur schwierig geschlossen zu behandeln sind.

Indikationen

Gemäß der AO-Kinderklassifikation der suprakondylären Humerusfrakturen vom Typ III und IV: Frakturen, welche nicht geschlossen mittels üblicher Repositionsmethoden reponierbar sind sowie Frakturen, die nicht mittels der üblichen, gekreuzten perkutanen Kirschner-Draht-Technik zu fixieren sind. Bei schweren Schwellungszuständen, offener Fraktur oder initial neurologischen und/oder vaskulären Problemen („pulseless pink hand“) sowie bei mehrfachverletzten Kindern, welche eine optimale Rehabilitation benötigen und die Extremität gipsfrei sein sollte. Bei Kindern mit Komorbiditäten (z. B. Anfälle, Spastizität), die eine bessere Stabilität benötigen.

Kontraindikationen

Prinzipiell keine Kontraindikationen

Operationstechnik

Im nichtreponierten Zustand unter Durchleuchtungskontrolle Einbringen einer einzelnen Schanz-Schraube in den lateralen (radialen) Aspekt des distalen Fragments, welches sich in der streng seitlichen Röntgenprojektion als „Sand-Uhr“- bzw. Kreisform des Capitulum humeri darstellt. Je nach Größe dieses distalen Fragments kann die Schanz-Schraube rein epiphysär oder metaphysär liegen. Danach in absolut streng seitlicher Projektion des distalen Humerus im Bereich des meta-diaphysären Übergangs Einbohren einer 2. Schanz-Schraube unabhängig von der Ersten, die möglichst rechtwinklig zur Längsachse des Humerus in der a.-p.-Ebene zu liegen kommen sollte, um spätere Manipulationen mittels „Joy-Stick“-Technik zu erleichtern. Sind die beiden Schanz-Schrauben mehr oder weniger in beiden Ebenen parallel, so ist die Fraktur praktisch anatomisch reponiert. Nach erreichter Reposition Feinjustierung aller Achskomponenten. Sicherung der Flexion/Extension mittels einem von radial, distal eingebrachten sog. Anti-Rotations-Kirschner-Drahts, der die Stabilität signifikant erhöht und eine Drehung des distalen Fragments um die einzelne Schanz-Schraube verhindert.

Postoperative Behandlung

Keine zusätzliche Gipsruhigstellung notwendig. Es sollte eine funktionelle Nachbehandlung erfolgen.

Ergebnisse

Gemäß unserer Langzeitstudien bewegen die meisten Kinder bereits zum Zeitpunkt der ambulanten Pin-Entfernung in der Frakturambulanz ihren Ellbogen weitgehend normal. Bei einer Follow-up-Zeit über 40 Monate hatten 30/31 Kindern eine seitengleiche Achse und Beweglichkeit.
OBJECTIVE

Closed, anatomical reduction and reliable fixation of type III and IV supracondylar fractures that are either difficult or impossible to treat with conventional methods.

INDICATIONS

According the Pediatric Comprehensive AO Classification for long bones this technique is preferred for type III and IV supracondylar fractures that cannot be reduced using closed standard manipulative techniques, where stable fixation using standard percutaneous wire configurations cannot be achieved, when severe swelling, open fracture, primary neurological or vascular problems ("pulseless pink hand") or multiple injuries indicate that optimal management of the injured limb should be free from cast. In patients with comorbidities (e.g., seizures or spasticity) requiring more stable fixation.

CONTRAINDICATIONS

In principle there are no contraindications.

SURGICAL TECHNIQUE

Prior to reduction of the fracture, fluoroscopically controlled insertion of a single Schanz screw into the lateral (radial) aspect of the distal fragment, which is defined by bulls eyeing the capitellum in the perfect lateral radiographic projection of the epiphysis, parallel to the physis. For very distal fractures this screw may be intra-epiphyseal, although usual placement is in the metaphysis just distal to the fracture line. After obtaining perfect lateral radiographic projection of the distal humeral metaphyseal-diaphyseal junction, a second Schanz screw is inserted independently into the proximal fracture fragment at the proximal end of the lateral supracondylar ridge in the sagittal plane perpendicular to the long axis of the humeral diaphysis. By bringing the screws parallel to each other in the coronal and transverse planes direct manipulations of the fragments and anatomical reduction using the so-called joystick technique is achieved. Fracture reduction can then be adjusted anatomically under fluoroscopic control and through clinical assessment. Once reduction is achieved the fragments have to be secured with a so-called "anti-rotation" K-wire. This wire significantly enhances stability and prevents pivoting of the fracture fragments around the Schanz screws in the sagittal plane and assists in prevention of medial collapse of the reduced fracture.

POSTOPERATIVE MANAGEMENT

No additional plaster cast fixation required; mobilization of the upper limb as comfort allows.

RESULTS

The majority of children have a normal range of motion at the time of external fixator removal. At follow-up (40 months), 30 of 31 children had normal function and a normal, anatomical axis as judged against the contralateral upper limb.
Date Issued
2014-02
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Language(s)
de
Author(s)
Slongo, Theddy  
Universitätsklinik für Kinderchirurgie  
Additional Credits
Universitätsklinik für Kinderchirurgie  
Journal
Operative Orthopädie und Traumatologie
Publisher
Springer-Medizin-Verlag
ISSN
0934-6694
Access(Rights)
Unknown
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify