  3. Reproducibility and reliability of flow quantification using CMR 2D-phase contrast and 4D-Flow in secondary mitral valve regurgitation.

Reproducibility and reliability of flow quantification using CMR 2D-phase contrast and 4D-Flow in secondary mitral valve regurgitation.

Details
Files
DOI
10.48620/89122
Publisher DOI
10.1007/s10554-025-03421-x
PubMed ID
40377789
Abstract
Accurate quantification of mitral valve regurgitation (MVR) is crucial for patient management. While different MVR quantification methods based on cardiac magnetic resonance imaging (CMR) exist, their reproducibility and reliability remain uncertain. This study aims to evaluate the reproducibility of different CMR 2D-phase contrast (PC) and 4D-flow MVR quantification methods. The inter-reader and intra-reader reproducibility were assessed using intraclass correlation coefficients (ICC). Seven methods were evaluated: 2D-PC standard (LVSV minus aortic flow), 2D-PC mitral-aortic (mitral inflow minus aortic flow), 2D-PC direct (quantifying mitral backflow), 4D-flow standard, 4D-flow mitral-aortic, 4D-flow direct, and volumetric method (LVSV minus RVSV) in 32 patients (74.8 ± 9.8 years, 28% females) with secondary MVR, analyzed independently by two experienced readers. A total of 26 patients were included in the analysis for 2D-PC and 15 for 4D-flow methods. Among all techniques, 2D-PC standard was the most reliable method with both good inter-reader (ICC = 0.85, p < 0.001) and intra-reader agreement (ICC = 0.87, p < 0.001). The 4D-flow standard (ICC = 0.97, p < 0.001) and the volumetric method (ICC = 0.81, p < 0.001) showed excellent and good intra-reader agreements, respectively, but only moderate inter-reader reproducibility (ICC = 0.52, p = 0.027 and ICC = 0.71, p < 0.001). In patients with secondary MVR, 2D-PC standard method demonstrated the highest reproducibility, while 4D-flow methods showed excellent intra-reader reliability but more variable inter-reader agreement. Standardized post-processing protocols and training would likely enhance the clinical application of these techniques. Future studies should investigate these methods in larger, diverse cohorts and correlate findings with clinical outcomes.
Date Issued
2025-07
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
2D-PC
•
4D-flow
•
Cardiovascular
•
Challenges
•
Data analysis
•
Flow
•
Heart
•
Validation
•
Valves
•
Velocity & flow
Language(s)
en
Author(s)
Safarkhanlo, Yasaman  orcid-logo
Clinic of Cardiology  
Boscolo Berto, Martina  
Clinic of Cardiology  
Spano, Giancarlo  
Clinic of Cardiology  
Bernhard, Benedikt  
Clinic of Cardiology  
Schütze, Jonathan  
Clinic of Cardiology - Universitätsklinik Insel Gruppe  
Stark, Anselm W.  
Clinic of Cardiology  
Praz, Fabien  
Clinic of Cardiology  
Shiri, Isaac  
Clinic of Cardiology  
Peters, Alan A.  
Institute of Diagnostic, Interventional and Paediatric Radiology  
Schaub, Christof  
Institute of Diagnostic, Interventional and Paediatric Radiology  
Peper, Eva S.  
Institute of Diagnostic, Interventional and Paediatric Radiology  
Garefa, Chrysoula  
Clinic of Cardiology  
Wahl, Andreas  
Clinic of Cardiology - Universitätsklinik Insel Gruppe  
Bastiaansen, Jessica A. M.  orcid-logo
Institute of Diagnostic, Interventional and Paediatric Radiology  
Gräni, Christoph  
Clinic of Cardiology  
Additional Credits
Clinic of Cardiology  
Institute of Diagnostic, Interventional and Paediatric Radiology  
Graduate School for Cellular and Biomedical Sciences (GCB)  
sitem Center for Translational Medicine and Biomedical Entrepreneurship  
Journal
The International Journal of Cardiovascular Imaging
Publisher
Springer
ISSN
1875-8312
1569-5794
Access(Rights)
Unknown
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify