  3. Functional assessment of myocardial ischaemia by intracoronary ECG.

Functional assessment of myocardial ischaemia by intracoronary ECG.

Details
Files
DOI
10.48350/151420
Publisher DOI
10.1136/openhrt-2020-001447
PubMed ID
33462106
Abstract
INTRODUCTION

In patients with chronic coronary syndrome, percutaneous coronary intervention targets haemodynamically significant stenoses, that is, those thought to cause ischaemia. Intracoronary ECG (icECG) detects ischaemia directly where it occurs. Thus, the goal of this study was to test the accuracy of icECG during pharmacological inotropic stress to determine functional coronary lesion severity in comparison to the structural parameter of quantitative angiographic per cent diameter stenosis (%S), as well as to the haemodynamic indices of fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR).

METHOD

The primary study endpoint of this prospective trial was the maximal change in icECG ST-segment shift during pharmacological inotropic stress induced by dobutamine plus atropine obtained within 1 min after reaching maximal heart rate(=220 - age). IcECG was acquired by attaching an alligator clamp to the angioplasty guidewire positioned downstream of the stenosis. For the pressure-derived stenosis severity ratios, coronary perfusion pressure and simultaneous aortic pressure were continuously recorded.

RESULTS

There was a direct linear relation between icECG ST-segment shift and %S: icECG=-0.8+0.03*%S (r2=0.164; p<0.0001). There were inverse linear correlations between FFR and %S: FFR=1.1-6.1*10-3*%S (r2=0.494; p<0.0001), and between iFR and %S: iFR=1.27-8.6*10-3*%S (r2=0.461; p<0.0001). Using a %S-threshold of ≥50% as the reference for structural stenosis relevance, receiver operating characteristics-analysis of absolute icECG ST-segment shift during hyperemia showed an area under the curve (AUC) of 0.678±0.054 (p=0.002; sensitivity=85%, specificity=50% at 0.34 mV). AUC for FFR was 0.854±0.037 (p<0.0001; sensitivity=64%, specificity=96% at 0.78), and for iFR it was 0.816±0.043 (p<0.0001;sensitivity=62%, specificity=96% at 0.83).

CONCLUSIONS

Hyperaemic icECG ST-segment shift detects structurally relevant coronary stenotic lesions with high sensitivity, while they are identified highly specific by FFR and iFR.
Date Issued
2021-01
Publication Type
Article
Subject(s)
600 Technology > 610 Medicine & health
Subjects
cardiac catheterisation coronary angiography coronary stenosis electrocardiography percutaneous coronary intervention
Language(s)
en
Author(s)
Bigler, Marius Reto  orcid-logo
Universitätsklinik für Kardiologie  
Stoller, Michael
Praz, Fabien Daniel  
Universitätsklinik für Kardiologie  
Siontis, George C M
Grossenbacher, Raphael
Tschannen, Christine
Seiler, Christian
Additional Credits
Universitätsklinik für Kardiologie  
Journal
Open Heart
Publisher
B M J Group
ISSN
2053-3624
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 24f0a9 [ 4.09. 8:55]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify