Comparing diagnostic accuracy of 18F-FDG-PET/CT, contrast enhanced CT and combined imaging in patients with suspected vascular graft infections.
Publisher DOI
PubMed ID
30426151
Abstract
BACKGROUND
To evaluate the diagnostic accuracy of positron emission tomography/computed tomography with 18F-fluorodeoxyglucose (PET/CT), contrast-enhanced CT (CE-CT), and a combined imaging approach (CE-PET/CT) in patients with suspected vascular graft infection (VGI).
METHODS
PET/CT and CE-CT were performed prospectively in 23 patients with suspected VGI. Diagnostic accuracy for PET/CT was assessed by using previously suggested cut-off points for maximum standardized uptake values (SUVmax) measured in the vicinity of the graft. Using a new 4-point scale for visual grading, two readers independently assessed the diagnostic accuracy for CE-CT and combined CE-PET/CT. Microbiological culture, obtained after open biopsy or graft explantation, and clinical follow-up of the patients served as the standard of reference.
RESULTS
Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and accuracy of PET/CT for the diagnosis of VGI was 100%, 50%, 100%, 72.2%, and 78.3%, using the most favorable SUVmax cut-off ≥ 4.9. Respective values for CE-CT were 100%, 50%, 100%, 72.2%, and 78.3% for reader 1, and 92.3%, 80%, 88.9%, 85.7%, and 86.9% for reader 2; while respective values for combined CE-PET/CT were 100%, 70%, 100%, 81.3%, and 86.9% for reader 1, and 100%, 80%, 100%, 86.7%, and 91.3% for reader 2. Additionally, imaging provided a conclusive clinical diagnosis in patients without graft infection (i.e., other sites of infection): five of ten patients with CE-CT, six of ten patients with PET/CT, and seven of ten patients with combined CE-PET/CT.
CONCLUSION
The diagnostic accuracy of combined CE-PET/CT in patients with suspected VGI is very high. The combination of the high sensitivity of PET/CT in detecting metabolically active foci in infection, and the high specificity of CE-CT in detecting anatomic alterations, appears to be the reason why combined imaging outperforms stand-alone imaging in diagnosing VGI and may be supportive in future decision-making of difficult cases of suspected VGI. Clinical Trials.gov Identifier: NCT01821664.
To evaluate the diagnostic accuracy of positron emission tomography/computed tomography with 18F-fluorodeoxyglucose (PET/CT), contrast-enhanced CT (CE-CT), and a combined imaging approach (CE-PET/CT) in patients with suspected vascular graft infection (VGI).
METHODS
PET/CT and CE-CT were performed prospectively in 23 patients with suspected VGI. Diagnostic accuracy for PET/CT was assessed by using previously suggested cut-off points for maximum standardized uptake values (SUVmax) measured in the vicinity of the graft. Using a new 4-point scale for visual grading, two readers independently assessed the diagnostic accuracy for CE-CT and combined CE-PET/CT. Microbiological culture, obtained after open biopsy or graft explantation, and clinical follow-up of the patients served as the standard of reference.
RESULTS
Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV), and accuracy of PET/CT for the diagnosis of VGI was 100%, 50%, 100%, 72.2%, and 78.3%, using the most favorable SUVmax cut-off ≥ 4.9. Respective values for CE-CT were 100%, 50%, 100%, 72.2%, and 78.3% for reader 1, and 92.3%, 80%, 88.9%, 85.7%, and 86.9% for reader 2; while respective values for combined CE-PET/CT were 100%, 70%, 100%, 81.3%, and 86.9% for reader 1, and 100%, 80%, 100%, 86.7%, and 91.3% for reader 2. Additionally, imaging provided a conclusive clinical diagnosis in patients without graft infection (i.e., other sites of infection): five of ten patients with CE-CT, six of ten patients with PET/CT, and seven of ten patients with combined CE-PET/CT.
CONCLUSION
The diagnostic accuracy of combined CE-PET/CT in patients with suspected VGI is very high. The combination of the high sensitivity of PET/CT in detecting metabolically active foci in infection, and the high specificity of CE-CT in detecting anatomic alterations, appears to be the reason why combined imaging outperforms stand-alone imaging in diagnosing VGI and may be supportive in future decision-making of difficult cases of suspected VGI. Clinical Trials.gov Identifier: NCT01821664.
Date Issued
2019-06
Publication Type
Article
Subject(s)
Subjects
CT Diagnostic accuracy FDG PET/CT Vascular graft infection
Language(s)
en
Author(s)
Husmann, Lars | |
Huellner, Martin W | |
Ledergerber, Bruno | |
Anagnostopoulos, Alexia | |
Stolzmann, Paul | |
Burger, Irene A | |
Rancic, Zoran | |
Hasse, Barbara |
Journal
European journal of nuclear medicine and molecular imaging
Publisher
Springer-Verlag
ISSN
1619-7070
Access(Rights)
open.access