• LOGIN
    Login with username and password
Repository logo

BORIS Portal

Bern Open Repository and Information System

  • Publications
  • Theses
  • Research Data
  • Projects
  • Organizations
  • Researchers
  • More
  • Collections
  • Statistics
  • LOGIN
    Login with username and password
Repository logo
Unibern.ch
  1. Home
  2. Publications
  3. Compliance of the L5-S1 spinal unit: a comparative study between an unconstrained and a partially constrained system

Compliance of the L5-S1 spinal unit: a comparative study between an unconstrained and a partially constrained system

Details
Files
DOI
10.7892/boris.36418
Publisher DOI
10.1007/s00586-004-0807-0
PubMed ID
15864671
Abstract
A comparison between an unconstrained and a partially constrained system for in vitro biomechanical testing of the L5-S1 spinal unit was conducted. The objective was to compare the compliance and the coupling of the L5-S1 unit measured with an unconstrained and a partially constrained test for the three major physiological motions of the human spine. Very few studies have compared unconstrained and partially constrained testing systems using the same cadaveric functional spinal units (FSUs). Seven human L5-S1 units were therefore tested on both a pneumatic, unconstrained, and a servohydraulic, partially constrained system. Each FSU was tested along three motions: flexion-extension (FE), lateral bending (LB) and axial rotation (AR). The obtained kinematics on both systems is not equivalent, except for the FE case, where both motions are similar. The directions of coupled motions were similar for both tests, but their magnitudes were smaller in the partially constrained configuration. The use of a partially constrained system to characterize LB and AR of the lumbosacral FSU decreased significantly the measured stiffness of the segment. The unconstrained system is today's "gold standard" for the characterization of FSUs. The selected partially constrained method seems also to be an appropriate way to characterize FSUs for specific applications. Care should be taken using the latter method when the coupled motions are important.
Date Issued
2006
Publication Type
Article
Subject(s)
500 Science > 570 Life sciences; biology
600 Technology > 610 Medicine & health
Subjects
Biomechanics
•
Spine
•
Kinematics
•
Torque
•
Degree of freedom
Language(s)
en
Author(s)
Charrière, Eric
Beutler, Thomas  
Institut für chirurgische Technologien und Biomechanik (ISTB)  
Caride, M
Mordasini, Philippe
Orr, T E
Zysset, Philippe  
Institut für chirurgische Technologien und Biomechanik (ISTB)  
Additional Credits
Institut für chirurgische Technologien und Biomechanik (ISTB)  
Journal
European spine journal
Publisher
Springer
ISSN
0940-6719
Access(Rights)
open.access
Show full item
BORIS Portal
Bern Open Repository and Information System
Build: 0eaa7c [ 7.08. 11:06]
Explore
  • Projects
  • Funding
  • Publications
  • Research Data
  • Organizations
  • Researchers
  • Audiovisual Material
  • Software & other digital items
  • Events
More
  • About BORIS Portal
  • BORIS Portal & Open Science
  • Send Feedback
  • Cookie settings
  • Service Policy
Follow us on
  • Mastodon
  • YouTube
  • LinkedIn
UniBe logo
Repository logo COAR Notify