Publication:
Durability of bioprosthetic aortic valve replacement in patients under the age of 60 years - 1-year follow-up from the prospective INDURE registry.

cris.virtualsource.author-orciddaf945c8-7ac0-47e5-b835-0a0b1091deaf
datacite.rightsopen.access
dc.contributor.authorMeuris, Bart
dc.contributor.authorRoussel, Jean-Christian
dc.contributor.authorBorger, Michael A
dc.contributor.authorSiepe, Matthias
dc.contributor.authorStefano, Pierluigi
dc.contributor.authorLaufer, Günther
dc.contributor.authorLanganay, Thierry
dc.contributor.authorTheron, Alexis
dc.contributor.authorGrabenwöger, Martin
dc.contributor.authorBinder, Konrad
dc.contributor.authorDemers, Philippe
dc.contributor.authorPessotto, Renzo
dc.contributor.authorvan Leeuwen, Wouter
dc.contributor.authorBourguignon, Thierry
dc.contributor.authorCanovas, Sergio
dc.contributor.authorMariscalco, Giovanni
dc.contributor.authorCoscioni, Enrico
dc.contributor.authorDagenais, Francois
dc.contributor.authorWendler, Olaf
dc.contributor.authorPolvani, Gianluca
dc.contributor.authorEden, Matthias
dc.contributor.authorBotta, Beate
dc.contributor.authorBramlage, Peter
dc.contributor.authorDe Paulis, Ruggero
dc.date.accessioned2024-10-25T16:57:38Z
dc.date.available2024-10-25T16:57:38Z
dc.date.issued2023-10-04
dc.description.abstractOBJECTIVES We report 1-year safety and clinical outcomes in patients <60 years undergoing bioprosthetic surgical aortic valve intervention. METHODS The INSPIRIS RESILIA Durability Registry (INDURE) is a prospective, multicentre registry to assess clinical outcomes of patients <60 years. Patients with planned SAVR with or without concomitant replacement of the ascending aorta and/or coronary bypass surgery were included. Time-related valve safety, haemodynamic performance, and quality of life (QoL) at 1 year were assessed. RESULTS 421 patients were documented with a mean age of 53.5 years, 76.5% being male, and 27.2% in NYHA class III/IV. Outcomes within 30 days included cardiovascular-related mortality (0.7%), time-related valve safety (VARC-2; 5.8%), thromboembolic events (1.7%), valve-related life-threatening bleeding (VARC-2; 4.3%), and permanent pacemaker implantation (3.8%). QoL was significantly increased at 6 months and sustained at 1 year. Freedom from all-cause mortality at 1 year was 98.3% (95%CI 97.1;99.6) and 81.8% were NYHA I vs. 21.9% at baseline. No patient developed structural valve deterioration Stage 3 (VARC-3). Mean aortic pressure gradient was 12.6 mmHg at 1 year and effective orifice area was 1.9 cm2. CONCLUSIONS The 1-year data from the INSPIRIS RESILIA valve demonstrate good safety and excellent haemodynamic performance as well as an early QoL improvement. CLINICALTRIALS NUMBER NCT03666741.
dc.description.sponsorshipUniversitätsklinik für Herzchirurgie
dc.identifier.doi10.48350/184936
dc.identifier.pmid37462612
dc.identifier.publisherDOI10.1093/icvts/ivad115
dc.identifier.urihttps://boris-portal.unibe.ch/handle/20.500.12422/168832
dc.language.isoen
dc.publisherOxford University Press
dc.relation.ispartofInterdisciplinary cardiovascular and thoracic surgery
dc.relation.issn2753-670X
dc.relation.organizationClinic of Heart Surgery
dc.subjectSurgical aortic valve replacement structural valve degeneration valve durability
dc.subject.ddc600 - Technology::610 - Medicine & health
dc.titleDurability of bioprosthetic aortic valve replacement in patients under the age of 60 years - 1-year follow-up from the prospective INDURE registry.
dc.typearticle
dspace.entity.typePublication
dspace.file.typetext
oaire.citation.issue4
oaire.citation.volume37
oairecerif.author.affiliationUniversitätsklinik für Herzchirurgie
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.contributor.rolecreator
unibe.date.licenseChanged2023-07-20 03:15:09
unibe.description.ispublishedpub
unibe.eprints.legacyId184936
unibe.refereedtrue
unibe.subtype.articlejournal

Files

Original bundle
Now showing 1 - 1 of 1
Name:
ivad115.pdf
Size:
2.51 MB
Format:
Adobe Portable Document Format
File Type:
text
License:
https://creativecommons.org/licenses/by/4.0
Content:
accepted

Collections