Experimental study of electric breakdowns in liquid argon at centimeter scale
Publisher DOI
Abstract
In this paper we present results on measurements of the dielectric strength of liquid argon near its boiling point and cathode-anode distances in the range of 0.1 mm to 40 mm with spherical cathode and plane anode. We show that at such distances the applied electric field at which breakdowns occur is as low as 40 kV/cm. Flash-overs across the ribbed dielectric of the high voltage feed-through are observed for a length of 300 mm starting from a voltage of 55 kV. These results contribute to set reference for the breakdown-free design of ionization detectors, such as Liquid Argon Time Projection Chambers (LAr TPC).
Date Issued
2014
Publication Type
Article
Language(s)
en
Author(s)
Additional Credits
Journal
Journal of instrumentation
Publisher
Institute of Physics Publishing IOP
ISSN
1748-0221
Access(Rights)
restricted